Pressure sensors

  1. MDA Series
  2. PT Series
  3. MDT series
  4. SPX series
  5. Echo Series
  6. Vertex Series
  7. Industrial series
  8. Injection Series
  9. Mercury Free Series

PT4656XL

The PT4656XL models represent an optimal solution for precise melt pressure measurement in nozzles or distribution channels within injection molding applications.

The flexible capillary extends from its electronic housing to the positioned tip in the machine melt, ensuring exceptional durability and prolonged sensor lifespan thanks to its robust construction.

1 "bending radius

Inconel 718 membrane

Cap nut for easy installation

Scanning accuracy ± 0.5%

Usable up to 400°C

Zero and range calibration

Optional output signal

CE EAC GOST ISO9001 RoHS2 SIL2

PT4194 (Oil) 4-20mA

PT4194 Sensors provide an industry standard 4-20 mA amplified signal designed to work with DCS and PLC.

 

It is a sensor with ± 0.5% accuracy ideal for the food or pharmaceutical industry requiring easy installation, repeatability and reliability. It is filled with mineral oil that meets the requirements of FDA 21 CFR 178.3620, 21 CFR 172.878 and 21 CFR 573.680.

Auto-Zero function

The cartridge meets FDA requirements

Scanning accuracy 0.5%

Output signal 4-20 mA

No calibration required

Ideal for medical and pharmaceutical applications

Excellent abrasion resistance

Auto-Zero

CE EAC GOST ISO9001 RoHS2 SIL2

PT4195 (Oil) 0-5 Vdc

PT4195 sensors provide a standard 0-5Vdc output signal designed to work with DCS and PLC.

 

It is a sensor with ± 0.5% accuracy ideal for the food or pharmaceutical industry, requiring easy installation, repeatability and reliability. It is filled with mineral oil that meets the requirements of both the USDA and the FDA.

Adjustable zero and span

The cartridge meets FDA and USDA requirements

Accuracy better than ± 0.5%

Stainless steel construction and wetted parts Coated with Dymax®

Output signal 0-5 Vdc

Internal calibration 80%

CE EAC GOST ISO9001 RoHS2 SIL2

PT4674 (4-20 mA)

Model PT4674 is a special variant of the pressure sensor with flexible capilary and exposed capillary, which has an output signal of 4-20 mA. It is used wherever a conventional sensor with a fixed rod or flexible capillary cannot be installed due to lack of space.The accuracy of this sensor is better than ±0.5%.

Accuracy ± 0.5%

4-20mA output signal

Internal 80% calibration

Adjustable zero and sensor range

Flexible capillary

Exposed capillary

CE EAC GOST ISO9001 RoHS2 SIL2

PT4675 (0-5 Vdc)

Model PT4675 is a special variant of the pressure sensor with flexible capillary and exposed capillary, which has a 0-5 VDC output signal and is used wherever a conventional fixed rod or flexible capillary sensor cannot be installed due to lack of space. The accuracy of this sensor is better than ±0.5%.

Scanning accuracy ± 0.5%

Output signal 0 to 5 Vdc

Internal 80% calibration

Adjustable zero and sensor range

Exposed capillary

CE EAC GOST ISO9001 RoHS2 SIL2

PT4676 (0-10Vdc)

Model PT4676 is a special variant of the pressure sensor with flexible capillary and exposed capillary, which has a 0 to 5 Vdc, 1 to 6 Vdc, 0 to10 Vdc, 1 to 11 Vdc outputs signal and is used wherever a conventional fixed rod or flexible capillary sensor cannot be installed due to lack of space. The accuracy of this sensor is better than ±0.5%.

Scanning accuracy ± 0.5%

Output signal 0 to 10 Vdc

Internal 80% calibration

Adjustable zero and sensor range

Exposed capillary

CE EAC GOST ISO9001 RoHS2 SIL2

PT4196 (Oil) 0-10 Vdc

PT4196 sensors provide a standard 0-10Vdc output signal designed to work with DCS and PLC.

 The PT4196 is a ± 0.5% accuracy sensor ideal for applications in the food and pharmaceutical industries requiring easy installation, repeatability and reliability. The output signal represents 0-10. The alternative filling of the sensor in the form of oil for the food industry meets the requirements set by the USDA and the FDA.

Accuracy better than ± 0.5%

Alternative charge (oil)

0 - 1000 to 0 - 10,000 psi

0-10 Vdc output signal

Meets FDA and USDA requirements

CE EAC GOST ISO9001 RoHS2 SIL2

PT130 | PT140 | PT150 | PT160 Hydraulic sensors

PT130 =  3 mV/V
PT140 =  0-5   VDC
PT150 =  0-10 VDC
PT160 =  4 - 20 mA

This range of hydraulic sensors is designed to measure pressure in injection molding applications. It has a very good resistance to cyclic pressure, which is characteristic of these applications and provide information on the change of the hyd profile. pressure together with information on the stability of the injection system

PT 130 = 3 mV/V

PT 140 = 5 Vdc

PT 150 = 10 Vdc

PT 160 = 4 to 20 mA

Accuracy ± 0.5%

Resistance up to 140°C

Stainless steel construction

Robust design

Internal calibration

Compact dimensions

CE EAC GOST ISO9001 RoHS2 SIL2

PT139 | PT139A

Dynisco PT139 and PT139A pressure sensors are designed to measure hydraulic pressure in extreme conditions for testing vehicles, stands and other hydraulic and pneumatic applications. These sensors withstand cyclic pressure and provide excellent performance during demanding industrial conditions.

Full power 3 mV/V

Accuracy better than ± 0.5%

The pressure range is from 0-15 PSI to 0-10,000 PSI

Pressure and vacuum support

Extended operating temperature range

Fully welded stainless steel construction

It resists strong shocks and vibrations

Internal 80% calibration

CE approval

CE EAC GOST ISO9001 RoHS2

PT199 Pressure sensor

The PT199 pressure sensor is designed to measure pressure on turbine systems. Provides information on pressure or temperature in gas or fuel systems such as gas turbines to regulate gas or fuel flow.

Stainless steel construction

Adjustable zero and upper range

Excellent temperature compensation

Ranges 0-15 PSI to 0-15000 PSI

Advanced electronic design

Accuracy ±0.25% PT199B, PT199S, APT199S

Accuracy ±0.5% PT199

CE EAC GOST ISO9001 RoHS2 SIL2

PT375 Pressure Transducer

The Dynisco PT 375 pressure transmitter is designed for applications requiring a zero volume pressure port, fast response time and strict cleanliness standards. The high-pressure metal-to-metal seal offers reliable pressure measurement of sludges, viscous liquids and other media that can be homogenized.

3 mv/v output

Accuracy ±0.50%

Pressure ranges 0-30,000 PSI

Iconel 718 pressure fitting

Zero volume pressure port

Meets cleanability standards

Metal-to-metal pressure seal

Internal 80% shunt calibration

CE EAC GOST ISO9001 RoHS2 SIL2

PT311JA Pressure sensor

The Dynisco PT311JA Washable Pressure Sensor is designed for applications requiring a zero volume pressure port. The recessed diaphragm improves the frequency response. The PT311JA has a full 3 mV / V output signal and offers reliable and accurate pressure measurement of gases, viscous liquids.

Flush diaphragm

Accuracy ±0.50%

Zero volume pressure port

15 to 10,000 psi

3 mV/V output

Internal shunt calibration