Model 24B Pressure Transducer
Viatran’s 24B is one of our most versatile pressure transducers for industrial applications. The 24B measures from 0-100 PSI to 0-30,000 PSI with standard linearity of ≤ ±0.25% FSO.
PERFORMANCE
| Full Scale Pressure Ranges: | 0-100 thru 15,000 PSIG (PSIS FOR ≥ 1500 PSI) (7 thru 1000 bar) | |
| Nonlinearity (Best Fit Straight Line) | ≤±0.25% FSO | |
| Hysteresis & Repeatability | ≤±0.10% FSO | |
| Full Scale Output (FSO) | 5 Vdc at 70°F (21°C) ≤±0.10% FSO | |
| Resolution | Infinite | |
| Long Term Stability | ≤±0.3% FSO per 6 months | |
| Compensated Temperature Range | 70°F to 170°F (21°C to 77°C) | |
| Process Media Temperature Range | -40°F to 250°F (-40°C to 121°C) | |
| Ambient Operating Temperature Range | -40°F to 185°F (-40°C to 85°C) | |
| Storage Temperature Limits | -40°F to 250°F (-40°C to 121°C) | |
| Temperature Effect on Zero | ≤±2.0% FSO per 100°F | |
| Temperature Effect on Span | ≤±2.0% FSO per 100°F | 
ELECTRICAL
| Supply Voltage: | 8 to 30 Vdc at 3.5 mA nominal, 5 mA max (12 to 30 Vdc for 10 Vdc output option | |
| Power Supply Regulation | ≤±0.01% FSO per volt change over the supply voltage range | |
| Output Signal | 0 - 5 Vdc standard (see options) | |
| Zero Adjustment | ±5% FSO min | |
| Circuit Protection | Input polarity may be reversed. Output may be short-circuited indefinitely Over voltage protection to 1000 volts according to EN61000-4-5 | |
| Insulation Resistance | <5 nSec to case ground | |
| Response Time | <2 mSec to reach 90% of full scale | |
| RFI / EMI Suppression | Bendix PT02E-10-6P, mates PT06E-10-6S (SR) | |
| Electrical Connection | Bendix PT02E-10-6P, mates PT06E-10-6S (SR) | |
| Pin Outs | Pin A + Power Pin B - Power Pin C + Signal Pin D - Signal Pin E No connection Pin F No connection Shell Groun | 
MECHANICAL
| Pressure Connection | 1/4" - 18 NPT female | |
| Proof Pressure | 1.5 times range or 20,000 PSI (1379 bar) max | |
| Burst Pressure | 3 times range or 35,000 PSI (2400 bar) max | |
| Pressure Cavity Volume | 4.5 ml | |
| Mounting | May be supported by process piping | 
MATERIALS OF CONSTRUCTION
| Wetted Materials: | Inconel X-750, heat treated per MR0175-2000 | |
| Enclosure Material: | 304 stainless steel | |
| Identification: | Laser etched onto body | |
| Shock Limitation: | 100 G’s | |
| Enclosure Rating: | NEMA 4X | |
| Weight: | 5.5 lbs nominal (2.4 kg) | |
| * Pending approvals | 
 | 