PT4195 (Oil) 0-5 Vdc
The PT4195 is a ± 0.5% accuracy sensor ideal for the food or pharmaceutical industries requiring easy installation, repeatability and reliability. The sensor cartridge is a mineral oil that meets the requirements of the USDA and the FDA. PT4195 sensors provide an industrial amplified 0-5 Vdc signal, which is designed to work with DCS and PLC. Optional thermocouples or RTDs are also available to provide melt temperature and pressure measured in one location. PT4195 is equipped with a 1 / 2-20UNF thread for easy mounting in standard mounting holes.
PERFORMANCE CHARACTERISTICS
Pressure range:
|
0 - 10 000 psi
|
|
Accuracy:
|
± 0.5% FSO, (Including linearity, repeatability and hysteresis)
|
|
Overload capacity:
|
2 x FSO (full range sensor)
|
|
Repeatability: | ± 0.2% FSO (full sensor range) | |
Sensor diaphragm: | Inconel 718 | |
Sensor connection: | 1/2"-20 UNF-2A nebo M18 x 1.5 | |
Mounting torque: | 500 inch/lbs. maximum | |
Sensor construction: | Sensor with rigid stem Sensor with rigid stem and flexible stem Combined sensor with rigid stem, flexible stem and built-in temperature sensor |
TEMPERATURE CHARACTERISTICS
Max. membrane temperature:
|
315°C
|
|
Zero shift (due to temperature):
|
Typical 65 psi/100°C
|
|
-------------------------------------------
|
------------------------------------------------------------------
|
|
Max. sensor body temperature: | 121°C | |
Zero shift (due to temperature) | ± 0.1% FS/°C max | |
Displacement sensitivity (due to temperature) | ± 0.04% FS/°C max |
ELEKTRICKÉ CHARAKTERISTIKY
Power supply:
|
11 - 36 Vdc
|
|
Output signal:
|
0 - 5 Vdc
|
|
Zero setting:
|
± 15% FSO
|
|
Connector: | 6 Bendix PIN connector | |
Insulation resistance: | 1000 megohms @ 50 Vdc | |
Resistance calibration (R-Cal): | 80% of duty. range ± 0.50% of the total range |
Certification & Approval
![]() |
EU Declaration of Conformity for Flush Mount mV/V Output |
![]() |
ISO 9001:2015 |
![]() |
EAC - The Eurasian Conformity mark |
![]() |
GOST Approval |
![]() |
RoHS Compliance Fact Sheet |
![]() |
Safety Integrity Level - SIL2 |