PT Series

  1. MDA Series
  2. PT Series
  3. MDT series
  4. SPX series
  5. Echo Series
  6. Vertex Series
  7. Industrial series
  8. Injection Series
  9. Mercury Free Series

Characteristics of the PT Series

All sensors in this series can be configured. Optional accessories offer a more resistant membrane against abrasive, aggressive materials or without mercury filling and much more.
Contact us, we will be happy to help you with the configuration.
 

TPT models are the same as PT, however are equipped with temperature sensors in the form of a thermocouple. J, K, T, E or PT 100 thermocouples are available.

Output signal

Sensor power supply

Pressure range

Units

Signal converter

10 - 12 VDC

0 - 30 000

PSI


PT 4654XL

The PT4654 models are ideal for measuring melt pressure in a nozzle or manifold for injection applications.

 

The flexible capillary extends from its electronics housing to the installed tip in the machine melt, which guarantees unrivaled strength and extended sensor life.

1 "bending radius

Inconel 718 membrane

Cap nut for easy installation

Scanning accuracy ± 0.5%

Usable up to 400°C

Zero and range calibration

4-20mA output signal
 

PT 467 XL

PT 467 XL- Sensor with flexible and exposed capillary


The PT 467XL series of pressure transmitters are the ideal choice for applications with high accuracy and minimal mounting space. The PT 467XL models have an accuracy of ± 0.5% of range and an exposed capillary with a diameter of 1.5 mm, which allows bending in a radius of 1/16 inch. The sensors are supplied with a Dymax® membrane, which ensures an increase in wear resistance and thus a longer service life. Sensors marked XL have a protector (flexible capillary) up to the tip of the sensor.

Output signal 3.33 mV/V

Accuracy ± 0.5% f.s.v.

Proven sensor design

Construction for hard-to-reach spaces

0-500 to 0-30,000 psi

Excellent thermal stability

R-Cal calibration 80%

PT4676 (0-10Vdc)

Model PT4676 is a special variant of the pressure sensor with exposed capillary, which has an output signal of 4-20 mA. It is used wherever a conventional sensor with a fixed rod or flexible capillary cannot be installed due to lack of space.

Scanning accuracy ± 0.5%

Output signal 0 to 10 Vdc

Internal 80% calibration

Adjustable zero and sensor range

Exposed capillary

PT4675 (0-5 Vdc)

Model PT4675 is a special variant of the pressure sensor with exposed capillary, which has an output signal of 0-5Vdc. It is used wherever a conventional sensor with a fixed rod or flexible capillary cannot be installed due to lack of space.

Scanning accuracy ± 0.5%

Output signal 0 to 5 Vdc

Internal 80% calibration

Adjustable zero and sensor range

Exposed capillary

PT4674 (4-20 mA)

Model PT4674 is a special variant of the pressure sensor with exposed capillary, which has an output signal of 4-20 mA. It is used wherever a conventional sensor with a fixed rod or flexible capillary cannot be installed due to lack of space.

Scanning accuracy ± 0.5%

4-20mA output signal

Internal 80% calibration

Adjustable zero and sensor range

Exposed capillary

PT130 | PT140 | PT150 | PT160 Hydraulic sensors

PT 130 = 3 mV / V
PT 140 = 5 V Dc
PT 150 = 10 V Dc
PT 160 = 4 to 20 mA


This range of hydraulic sensors is designed to measure pressure in injection molding applications. It has a very good resistance to cyclic pressure, which is characteristic of these applications and provide information on the change of the hyd profile. pressure together with information on the stability of the injection system.

PT 130 = 3 mV/V

PT 140 = 5 Vdc

PT 150 = 10 Vdc

PT 160 = 4 to 20 mA

Accuracy ± 0.50%

Resistance up to 140°C

Stainless steel construction

Robust design

Internal calibration

Compact dimensions

PT4196 (Oil) 0-10 Vdc

PT4196 sensors provide a standard 0-10Vdc output signal designed to work with DCS and PLC.

 The PT4196 is a ± 0.5% accuracy sensor ideal for applications in the food and pharmaceutical industries requiring easy installation, repeatability and reliability. The output signal represents 0-10. The alternative filling of the sensor in the form of oil for the food industry meets the requirements set by the USDA and the FDA.

Accuracy better than ± 0.5%

Alternative charge (oil)

0 - 1000 to 0 - 10,000 psi

0-10 Vdc output signal

Meets FDA and USDA requirements

PT4195 (Oil) 0-5 Vdc

PT4195 sensors provide a standard 0-5Vdc output signal designed to work with DCS and PLC.

 

It is a sensor with ± 0.5% accuracy ideal for the food or pharmaceutical industry, requiring easy installation, repeatability and reliability. It is filled with mineral oil that meets the requirements of both the USDA and the FDA.

Adjustable zero and span

The cartridge meets FDA and USDA requirements

Accuracy better than ± 0.5%

Stainless steel construction and wetted parts Coated with Dymax®

Output signal 0-5 Vdc

Internal calibration 80%

PT 4194 (Oil) 4-20mA

PT4194 sensors provide an industry standard 4-20 mA amplified signal designed to work with DCS and PLC.

 

It is a sensor with ± 0.5% accuracy ideal for the food or pharmaceutical industry requiring easy installation, repeatability and reliability. It is filled with mineral oil that meets the requirements of FDA 21 CFR 178.3620, 21 CFR 172.878 and 21 CFR 573.680.

Auto-Zero function

The cartridge meets FDA requirements

Scanning accuracy 0.5%

Output signal 4-20 mA

No calibration required

Ideal for medical and pharmaceutical applications

Excellent abrasion resistance

Auto-Zero

PT 418 | PT419 | TPT419 (Oil)

PT 418 - Sensor with rigid stem
PT 419 - Sensor with rigid stem and flexible stem
TPT 419 - Combined sensor with rigid stem, flexible stem and built-in temperature sensor
 

Model PT418 | PT419 | TPT419 uses mineral oil as a filler, which meets the requirements of the FDA and USDA and at the same time allows accurate pressure sensing in processes where it is not possible to use mercury fillings. These models are ideal for medical and food or packaging applications.

Output signal 3.33 mV/V

Accuracy better than 0.50%

Alternative filler (oil)

0-1000 to 0-10,000 psi

The filling material meets the requirements of the FDA and USDA

Power supply 10-12 Vdc

Units - PSI

8 Pin connector

Shunt calibration

PT 415D (NaK)

PT415D - Washable sensor with rigid stem and (NaK) filling.


The PT415D pressure transmitter is the ideal choice for food and medical applications that require high accuracy and easy maintenance. It is a washable sensor with insulated wiring type 1/2-14 NPT or an optional 6-pin hermetically insulated bendix connector. PT 415D contains a high temperature fill (NaK, sodium potassium) and an Inconel membrane. Meets FDA and USDA hygiene regulations and requirements.

Output signal 3.33mV/V

Accuracy better than 0.50%

Washable construction

FDA Certification - (GRAS) for food and pharmaceutical applications

Power supply 10-12 Vdc

Units - PSI

Shunt calibration

PT 410 | PT412 | TPT412 (NaK)

PT 410 - Sensor with rigid stem
PT 412 - Sensor with rigid stem and flexible stem
TPT 412 - Combined sensor with rigid stem, flexible stem and built-in temperature sensor


The PT 41x series is a sensor with ± 0.50% accuracy, which is ideal for food or medical applications. Its alternative filling (NaK), which replaces mercury.

Accuracy better than ± 0.50%

Applicability up to 538°C

NaK fill

Inconel membrane

3.33 mV/V output signal