Pressure sensors

  1. MDA Series
  2. PT Series
  3. MDT series
  4. SPX series
  5. Echo Series
  6. Vertex Series
  7. Industrial series
  8. Injection Series
  9. Mercury Free Series

SPX-5 Series

The SPX 5 Series is an intelligent range of sensors with a 4-20 mA output signal that incorporates DynalarityTM technology. Dynisco's innovation uses an advanced logarithm that linearizes fluctuations due to process effects on the sensor.

4-20 mA output signal

Accuracy better than 0.25%

Turndown 6 - 1

Optional configuration for use in potentially explosive atmospheres

Remote configurability via HART communication

Compatible for DSC or PLC systems

SPX-4 Series

The Dynisco SPX-4 Series is an intelligent pressure transmitter with a 4-20 mA output signal designed for use in hazardous, potentially explosive environments and is available with a variety of process and electrical connections.

4-20 mA output signal

Accuracy better than 0.15%

Turndown 6 - 1

Optional configuration for use in potentially explosive atmospheres

Remote configurability via HART communication

Compatible for DSC or PLC systems

SPX-T - 3 Series

TSPX-T (Series 3) is an intelligent series of sensors that includes temperature compensation and Dynisco Innovation - DynaLarity ™. The SPX-T delivers the most powerful sensors in the range. Temperature compensation is based on RTD measurements that compensate for temperature changes that reduce temperature variations and increase accuracy. There is no need to perform a temperature calibration after installing the sensor. 4-20 mA output signal.

4-20 mA output signal

Accuracy better than 0.15%

Turndown 6 - 1

Optional configuration for use in potentially explosive atmospheres

Remote configuration ability via HART communication

Compatible for DSC or PLC systems

SPX-2 Series

The SPX-2 series is an intelligent pressure transmitter with a 4-20mA output signal designed for demanding applications and is available with various processes and electrical connections.

The SPX - 2 series is a robust welded construction and certified for use in the explosion hazard zone.

4-20mA output signal

Accuracy better than 0.25%

Turndown 6 - 1

Optional configuration for use in hazardous environments

Remote configuration via HART

Output supplied directly to DSC or PLC

MDT 467

MDT 467 - Sensor with flexible and exposed capillary
 

Sensor with amplifier (signal converter) in version with flexible capillary and exposed membrane. Scanning accuracy better than 1.00% of range. Power supply via 10-36 Vdc. Membrane made of 15-5 PH material and coated with DyMAX®. The length of the fixed rod can be made and adjusted to the required size.

Output signal optional

Accuracy better than 1.00%

Power supply 10 -36 V dc

6 Pin connector

R-Cal calibration

MDT 435

MDT 435 - Sensor with flexible and exposed capillary
 

Sensor with an amplifier (signal converter) in a version with flexible capillary and exposed membrane. Scanning accuracy better than 0.50% of the range. Power supply via 10-36 Vdc. Membrane made of 15-5 PH material and coated with DyMAX®. The length of the fixed rod can be made and adjusted to the required size.

Output signal optional

Accuracy better than 0.50%

Power supply 10 -36 V dc

6 Pin connector

R-Cal calibration

MDT 460 | 462 | TDT 463

MDT 460 - Sensor with rigid stem
MDT 462 - Sensor with flexible capillary.
TDT 463 - Sensor with flexible capillary and temperature sensor.


Sensor with integrated amplifier (signal converter). Scanning accuracy better than 1.00% of range. Power supply via 10-36 Vdc. Membrane made of 15-5 PH material and coated with DyMAX®. The length of the fixed rod can be made and adjusted to the required size.

Output signal according to configuration

Accuracy better than 1.00%

Power supply 10 -36 V dc

6 Pin connector

R-Cal calibration

MDT 420 | 422 | TDT 432

MDT 420 - Sensor with rigid stem
MDT 422 - Sensor with flexible capillary.
TDT 432 - Sensor with flexible capillary and temperature sensor.
 

Sensor with integrated amplifier (signal converter). Scanning accuracy better than 0.50% of range. Power supply via 10-36 Vdc. Membrane made of 15-5 PH material and coated with DyMAX®. The length of the fixed rod can be made and adjusted to the required size.

Output signal according to configuration

Accuracy better than 0.50%

Power supply 10 -36 V dc

6 Pin connector

R-Cal calibration

PT4676 (0-10Vdc)

Model PT4676 is a special variant of the pressure sensor with exposed capillary, which has an output signal of 4-20 mA. It is used wherever a conventional sensor with a fixed rod or flexible capillary cannot be installed due to lack of space.

Scanning accuracy ± 0.5%

Output signal 0 to 10 Vdc

Internal 80% calibration

Adjustable zero and sensor range

Exposed capillary

PT4675 (0-5 Vdc)

Model PT4675 is a special variant of the pressure sensor with exposed capillary, which has an output signal of 0-5Vdc. It is used wherever a conventional sensor with a fixed rod or flexible capillary cannot be installed due to lack of space.

Scanning accuracy ± 0.5%

Output signal 0 to 5 Vdc

Internal 80% calibration

Adjustable zero and sensor range

Exposed capillary

PT4674 (4-20 mA)

Model PT4674 is a special variant of the pressure sensor with exposed capillary, which has an output signal of 4-20 mA. It is used wherever a conventional sensor with a fixed rod or flexible capillary cannot be installed due to lack of space.

Scanning accuracy ± 0.5%

4-20mA output signal

Internal 80% calibration

Adjustable zero and sensor range

Exposed capillary

PT130 | PT140 | PT150 | PT160 Hydraulic sensors

PT 130 = 3 mV / V
PT 140 = 5 V Dc
PT 150 = 10 V Dc
PT 160 = 4 to 20 mA


This range of hydraulic sensors is designed to measure pressure in injection molding applications. It has a very good resistance to cyclic pressure, which is characteristic of these applications and provide information on the change of the hyd profile. pressure together with information on the stability of the injection system.

PT 130 = 3 mV/V

PT 140 = 5 Vdc

PT 150 = 10 Vdc

PT 160 = 4 to 20 mA

Accuracy ± 0.50%

Resistance up to 140°C

Stainless steel construction

Robust design

Internal calibration

Compact dimensions