Model 555 Pressure Transmitter
Designed for harsh abrasive slurry, the 555 has a unique feature which allows for wet installation in less than an hour through the use of a pipe saddle with integral shutoff. External adjustments and corrosive resistant wetted materials make this an excellent choice for pulp and paper, waste water processing, slurry and sludge measurements.
PERFORMANCE
| Full Scale Pressure Ranges | 0-50, 100, 150, 200, 250, 300, 500, PSIS | |
| Combined Accuracy  (Non-Linearity, Hysteresis and repeatability)  | 
			50 - 100 PSI ≤±.5% FSO 150 - 500 PSI ≤±.3% FSO  | 
		|
| Full Scale Output (FSO) | 16 mA at 70°F (21°C) | |
| Long Term Stability | ≤±0.5% FSO per 6 months | |
| Pressure Connection Effect Zero Balance | ≤±1% FSO | |
| Response Time (Mechanical & Eletrical Combined)  | 
			<20 mSec to reach 90% of Full Scale | |
| Temperature Effect on Zero | ±1% FSO per 100°F (37°C) | |
| Temperature Effect on Span | ±1% FSO per 100°F (37°C) | |
| Combined at 4:1 Range Down | 70°F to 170°F (21°C to 77°C) | |
| Compensated Teperature Range | 185°F (85°C) - Ambient | |
| Maximum Operating Temperature | 250°F (121°C) - Fluid | |
| Minimum Operating Temperature | -40°F (-40°C) | |
| Storage Temperature Limits | -65°F to 250°F (-53°C to 121°C) | 
ELECTRICAL
| 
			 Supply Voltage: 
			 | 
			
			 12 to 30 Vdc 
			 | 
		|
| 
			 Power Consumption  
			 | 
			
			 ≤±0.02% FSO per volt 
			 | 
		|
| 
			 Output Signal 
			 | 
			
			 4-20 mA at 70°F (21°C) 
			 | 
		|
| Load Impedance | 900 Ohms maximum at 30 Vdc | |
| Elevation | -100% of FSO | |
| Suppression | +50% of FSO | |
| Span Adjustment | Rangeable down 4:1 from standard range | |
| Range Calibration Signal | 20% of FSPR externally switched | |
| Calibration Signal Accuracy | ±1.0% FSO. The exact signal to pressure correlation is provided with each unit | |
| Circuit Protection | Varistor protected across the input leads for surges above 40V and currents to 250 Amps Peak with a pulse width of 20 µSec. Reverse polarity protected | |
| Bridge Resistance | 5K Ohms nominal | |
| Insulation Resistance | ≥200 MegOhms to case ground (≤5 nS) | |
| RFI/EMI | Negligible to 500 MHz at 5 Watts direct contact | |
| Electrical Connection | 1/2” NPT (M), 18 AWG, 72” | |
| Wire Color Codes | 
			 Red +Power/Signal Black -Power/Signal Green Case Ground  | 
		
MATERIALS OF CONSTRUCTION
| 
			 Enclosure Materials 
			 | 
			
			 Inconel X750 and 316L stainless steel 
			 | 
		|
| 
			 Wetted Materials 
			 | 
			
			 Inconel X750 and 316L stainless steel 
			 | 
		|
| 
			 Enclosure Classification 
			 | 
			
			 NEMA/Type 4X (1P68) 
			 | 
		
MECHANICAL
| 
			 Pressure Connection: 
			 | 
			
			 100 - 1000 PSI Flush Diaphragm 
			 | 
		|
| 
			 Proof Pressure: 
			 | 
			
			 1.5 times URL 
			 | 
		|
| 
			 Burst Pressure: 
			 | 
			
			 ≥ 3 times rated URL 
			 | 
		|
| Shock Limitation | 100 g's | |
| Weight | 70 oz (2kg) | 
CERTIFICATIONS
| 
			 FM 
			 | 
			
			 Intrinsic Safety: Class I, II, III, Division 1, Groups A-G, and AEx ia IIC, T4 at Ta=80ºC, T5 at Ta=40ºC, Indoor and Outdoor NEMA/Type 4X Hazardous Locations 
			Nonincendive: Class I,II,III Div. 2, Groups A-G and Class I, Zone 2, Group IIC, T4 at Ta=80ºC, T5 at Ta=40ºC 
			 | 
		|
| 
			 CSA (Pending) 
			 | 
			
			 Intrinsic Safety: Class I, Div. 1, A-D Class II, E-G, Class III, Ex ia IIC T4 at Ta=80ºC, T5 at Ta=40ºC 
			 | 
		|
| 
			 ATEX 
			 | 
			
			 Intrinsic Safety: II 1 G EEx ia IIC, -20ºC T4, Ta 50ºC 
			 | 
		|
| CE | EMC Directive 89/336/EEC and Low Voltage Directive 72/23/EEC EN 61010-101993/A2:1995: Low Voltage Standard EN 61326: EMC Conformity Standard PED Directive 97/23/EC EMC Directive 89/336/EEC  | 
		
OPTIONS
| 
			 BB 
			 | 
			
			 Mini change electrical connector 
			 | 
		|
| 
			 BP 
			 | 
			
			 Micro change electrical connector 
			 | 
		|
| 
			 CL 
			 | 
			
			 Extra lead length (6 ft standard) 
			 | 
		|
| DG | Improved temperature and compensation | |
| DK | Special shunt calibration | |
| EA | Special calibration run | |
| NG | ATEX Flameproof label | |
| NH | Customer specified identification | |
| NJ | CE label | |
| NK | ATEX Intrinsic Safety label | |
| NSR | Non standard range | |
| NX | CSA Intrinsic Safety label | |
| NZ | FM Nonincendive label | |
| TF | FM Intrinsic Safety label | |
| TJ | CSA Div / Zone 2 | |
| TW | Russia Intrinsic Safety | |
| VD | G2” retaining nut | |
| Z () | Alternate electrical connection | |
| ZU | irect coupled cable | 
ACCESSORIES
| 
			 Pipe Saddle with shutoff 
			 | 
			||
| 
			 Conduit connection box 
			 | 
			||
| 
			 Calibration text fixture 
			 | 
			