Model 570 Pressure Transmitter
All welded construction and stainless steel surfaces makes the 570 ideal for corrosive environments. The transmitters O-ring free design ensures reliability with corrosive media. Viatran’s 570 FM approved labelled units are designed to meet NEC/API Dual Seal requirements. For the most corrosive environments, Hastelloy, Inconel, and 316 SS wetted parts are available.
PERFORMANCE
Full Scale Pressure Ranges | 0-100 thru 0-100K PSIS (0-6.89 thru 0-6894 bar) | |
Linearity (Best Fit Straight Line) |
0-100 PSI (0-6.89 bar) ±0.5% 150-10K PSI (10.3-6.89 bar) ±0.2% 15K-100K PSI (1034-6894 bar) ±0.25 |
|
Hysteresis | 4-20 mA (16 mA FSO) | |
Repeatability | ±1% FSO | |
Full Scale Output (FSO) | <2 mSec to reach 90% FSO | |
Zero and Span Balance | ≤±1% FSO per 100°F (55.5°C) | |
Long Term Stability | ≤±1% FSO per 100°F (55.5°C) | |
Response Time | 70°F to 170°F (21°C to 76°C) | |
Temperature Effect on Zero | -40°F to 185°F (-40°C to 85°C) | |
Temperature Effect on Span | -65°F to 185°F (-53°C to 85°C) | |
Compensated Temperature | -40°F to 190°F (-40°C to 87°C) | |
Operating Temperature | -40°F to 190°F (-40°C to 87°C) | |
Storage Temperature Limit | -65°F to 250°F (-53°C to 121°C) |
ELECTRICAL
Supply Voltage:
|
12 to 30 Vdc
|
|
Power Supply Regulation Effect
|
≤±0.02% FSO per Volt
|
|
Output Signal
|
4 - 20 mA
|
|
Bridge Impedance | 5000 Ohms nominal | |
Circuit Protection | Varistor protected across the input leads for surges above 40 V and currents to 250 Amps peak with a pulse width of 20 μSecs. Reverse polarity protected. | |
Insulation Resistance | >200 MegOhms to case ground | |
Electrical Connection - BH (Standard) |
1/2" NPT (M), 18 AWG wire, 72" |
|
Wire Color Codes |
Red +Power/Signal Black -Power/Signal Green Case ground White No Connection |
MATERIALS OF CONSTRUCTION
Enclosure
|
0-100 thru 0-15K PSI
15-5 PH and 316 stainless steel (0-6.8 thru 0-1034 bar) 0-20K thru 0-100K PSI 316 SST and PH 13-8 Mo SST (0-1378 thru 0-6894 bar) |
|
Wetted Parts
|
0-100 thru 0-15K PSI
15-5 PH stainless steel (0-6.8 thru 0-1034 bar) 0-20K thru 0-100K PSI PH 13-8 Mo SST (0-1378 thru 0-6904 bar) |
|
Shock Limitation
|
100 G’s
|
|
Weight | 24 oz. (0.680 kilograms) | |
Identification | Laser etched onto body | |
Enclosure | Classification NEMA 4X |
MECHANICAL
Pressure Connection:
|
0-50 thru 0-15K PSI
1/4" - 18 NPT Female (0-3.3 thru 0-1034 bar) 0-20K thru 0-50K PSI 1/4" F250-C High Pressure Tube (0-1378 thru 0-3447 bar 0-60K thru 0-100K PSI 5/16" F312C High Pressure Tube (0-4136) thru 0-6894 bar) |
|
Proof Pressure:
|
0-100 thru 0-15K PSI
1.5 times FSPR or 20K PSI (1378 bar), (0-6.8 thru 0-1034 bar) whichever is less 0-20K thru 0-100K PSI 1.2 times FSP (0-1378 thru 0-6894 bar) |
|
Burst Pressure:
|
0-100 thru 0-15K PSI
≥ 2.3 to 5 times FSPR dependent on (0-6.8 thru 0-10342 bar) sensor 0-20K thru 0-100K PSI 1.5 times FSPR or 125K PSI (8618 bar) (0-1378 thru 0-6894 bar) whichever is less |
|
Mounting | Supported by process piping or optional mounting bracket | |
Identification | Laser etched onto body |
OPTIONS
DF
|
Bleed port (10K PSI and below)
|
|
DG
|
Improved temperature compensation (<± 0.5% FSO/100°F for zero/span)
|
|
DH
|
Special range
|
|
DQ | Cleaning for oxygen service | |
EA | Special calibration run | |
JJ | Direct mount indicator with explosion proof housing | |
JS | Direct mount indicator | |
KN | IECEx flameproof label | |
ME | CSA explosion proof label | |
MR | Modified electrical damping | |
NG | ATEX flameproof label | |
NH | Customer specified identification | |
NJ | CE label | |
NK | ATEX intrinsic safety label | |
NX | CSA intrinsic safety label | |
NY | FM explosion proof label | |
NZ | FM nonincendive label | |
PW | 1/8 DIN digital indicator (consult factory) | |
QA | 316 stainless steel wetted parts | |
QB | Inconel (X-750) wetted parts | |
QC | Hastelloy (C-276) wetted parts | |
TF | FM intrinsic safety label | |
Y () | Alternate pressure ports | |
Note: | Application of some available options may affect standard performance. Consult your Viatran Representative for details. |