Model 709 Hammer Union Pressure Transmitter
709 is a 0-5Vdc output hammer union transmitter to monitor pump pressures in oil servicing applications like drilling, cementing, and hydrofracturing. Available with hazardous location approvals and a variety of electrical connections.
PERFORMANCE
Full Scale Pressure Ranges:
|
0-5K, 10K, 15K, 20K PSIG (0-345, 689, 1034, 1379 bar)
|
|
Combined Accuracy (BFSL):
|
(Non-Linearity, Hysteresis & Repeatability) ≤ ± 0.25% FSO
|
|
Full Scale Output (FSO):
|
5 Vdc ±1% FSO
|
|
Zero Balance: | 0 Vdc ±1% FSO | |
Compensated Temperature Range: | -20°F to 185°F (-29°C to 85°C) | |
Operating Temperature Range: | -40°F to 250°F (-40°C to 121°C) | |
Storage Temperature Range: | -67°F to 302°F (-55°C to 150°C) | |
Long Term Stability (%FSO): | ≤±0.25% FSO per 6 months | |
Response Time: | ≤2.5 mSec to reach 90% of FSO | |
Thermal Effect on Zero: | ≤±1% FSO per 100°F (37°C) | |
Thermal Effect on Span: | ≤±1% FSO per 100°F (37°C) |
ELECTRICAL
Output Signal:
|
0 - 5 Volts at 70°F (21°C)
|
|
Supply Voltage:
|
9-30 Vdc (10.5 to 28 Vdc w/approval)
|
|
Power Supply Regulation:
|
≤±0.01% FSO per Volt
|
|
Load Impedance: | 410K Ohms minimum | |
Circuit Protection: | Varistor protected across the input leads for surges above 1000V at 50 microseconds | |
Insulation Resistance: | ≥100 MegOhms to case ground | |
Calibration Power : | Short pins E & F | |
Calibration Signal Accuracy: | ≤±0.2% FSO. The exact signal to pressure correlation is provided with each unit | |
Bridge Resistance: | 10K Ohms nominal | |
Standard Electrical Connection: | Mates with Bendix P/N PT06E-10-6S or equivalent | |
PIN OUTS: | PIN A +Power PIN B -Power PIN C +Signal PIN D -Signal PIN E Calibration PIN F Calibration Some models are provided with customer specified wiring. Consult Viatran for exact wiring connections. |
MECHANICAL
Standard Pressure Port:
|
Male hammer union 2 inch #1502
|
|
Pressure Cavity Volume:
|
0.4 cubic inches
|
|
Zero Effect from Installation:
|
0.3% FSO w/200 ft-lbs torque on union #2202
|
|
Proof Pressure: | 1.67 times the FS or 22.5K PSI (1550 bar) for union #1502 30K PSI (2068 bar) for union #2002 whichever is less |
|
Burst Pressure: |
≥3 times FSPR, limited by union #1502: 22.5K PSI (1550 bar) |
MATERIALS OF CONSTRUCTION
Wetted Materials: |
Inconel X-750, heat treated per MR0175-2000
|
|
Enclosure Material: |
304 stainless steel
|
|
Identification:
|
Laser etched onto body
|
|
Enclosure Rating: | NEMA 4X | |
Weight: | 5.5 lbs nominal (2.4 kg) | |
Shock Limitation: |
100 G’s |
OPTIONS
DH
|
Special range
|
|
EA
|
Special calibration ru
|
|
NJ |
CE label
|
|
NX
|
CSA Intrinsic Safety label | |
TF
|
FM Intrinsic Safety label | |
TP
|
Low cavity volume sensor design |
|
TW
|
Russia Intrinsic Safety | |
ZQ
|
CG379-C-145-2P (Glenair) electrical connector | |
ZT
|
REC-M-10TP-N-04-16 (Jupiter) connector |