Model 555 Pressure Transmitter
Designed for harsh abrasive slurry, the 555 has a unique feature which allows for wet installation in less than an hour through the use of a pipe saddle with integral shutoff. External adjustments and corrosive resistant wetted materials make this an excellent choice for pulp and paper, waste water processing, slurry and sludge measurements.
PERFORMANCE
Full Scale Pressure Ranges | 0-50, 100, 150, 200, 250, 300, 500, PSIS | |
Combined Accuracy (Non-Linearity, Hysteresis and repeatability) |
50 - 100 PSI ≤±.5% FSO 150 - 500 PSI ≤±.3% FSO |
|
Full Scale Output (FSO) | 16 mA at 70°F (21°C) | |
Long Term Stability | ≤±0.5% FSO per 6 months | |
Pressure Connection Effect Zero Balance | ≤±1% FSO | |
Response Time (Mechanical & Eletrical Combined) |
<20 mSec to reach 90% of Full Scale | |
Temperature Effect on Zero | ±1% FSO per 100°F (37°C) | |
Temperature Effect on Span | ±1% FSO per 100°F (37°C) | |
Combined at 4:1 Range Down | 70°F to 170°F (21°C to 77°C) | |
Compensated Teperature Range | 185°F (85°C) - Ambient | |
Maximum Operating Temperature | 250°F (121°C) - Fluid | |
Minimum Operating Temperature | -40°F (-40°C) | |
Storage Temperature Limits | -65°F to 250°F (-53°C to 121°C) |
ELECTRICAL
Supply Voltage:
|
12 to 30 Vdc
|
|
Power Consumption
|
≤±0.02% FSO per volt
|
|
Output Signal
|
4-20 mA at 70°F (21°C)
|
|
Load Impedance | 900 Ohms maximum at 30 Vdc | |
Elevation | -100% of FSO | |
Suppression | +50% of FSO | |
Span Adjustment | Rangeable down 4:1 from standard range | |
Range Calibration Signal | 20% of FSPR externally switched | |
Calibration Signal Accuracy | ±1.0% FSO. The exact signal to pressure correlation is provided with each unit | |
Circuit Protection | Varistor protected across the input leads for surges above 40V and currents to 250 Amps Peak with a pulse width of 20 µSec. Reverse polarity protected | |
Bridge Resistance | 5K Ohms nominal | |
Insulation Resistance | ≥200 MegOhms to case ground (≤5 nS) | |
RFI/EMI | Negligible to 500 MHz at 5 Watts direct contact | |
Electrical Connection | 1/2” NPT (M), 18 AWG, 72” | |
Wire Color Codes |
Red +Power/Signal Black -Power/Signal Green Case Ground |
MATERIALS OF CONSTRUCTION
Enclosure Materials
|
Inconel X750 and 316L stainless steel
|
|
Wetted Materials
|
Inconel X750 and 316L stainless steel
|
|
Enclosure Classification
|
NEMA/Type 4X (1P68)
|
MECHANICAL
Pressure Connection:
|
100 - 1000 PSI Flush Diaphragm
|
|
Proof Pressure:
|
1.5 times URL
|
|
Burst Pressure:
|
≥ 3 times rated URL
|
|
Shock Limitation | 100 g's | |
Weight | 70 oz (2kg) |
CERTIFICATIONS
FM
|
Intrinsic Safety: Class I, II, III, Division 1, Groups A-G, and AEx ia IIC, T4 at Ta=80ºC, T5 at Ta=40ºC, Indoor and Outdoor NEMA/Type 4X Hazardous Locations
Nonincendive: Class I,II,III Div. 2, Groups A-G and Class I, Zone 2, Group IIC, T4 at Ta=80ºC, T5 at Ta=40ºC
|
|
CSA (Pending)
|
Intrinsic Safety: Class I, Div. 1, A-D Class II, E-G, Class III, Ex ia IIC T4 at Ta=80ºC, T5 at Ta=40ºC
|
|
ATEX
|
Intrinsic Safety: II 1 G EEx ia IIC, -20ºC T4, Ta 50ºC
|
|
CE | EMC Directive 89/336/EEC and Low Voltage Directive 72/23/EEC EN 61010-101993/A2:1995: Low Voltage Standard EN 61326: EMC Conformity Standard PED Directive 97/23/EC EMC Directive 89/336/EEC |
OPTIONS
BB
|
Mini change electrical connector
|
|
BP
|
Micro change electrical connector
|
|
CL
|
Extra lead length (6 ft standard)
|
|
DG | Improved temperature and compensation | |
DK | Special shunt calibration | |
EA | Special calibration run | |
NG | ATEX Flameproof label | |
NH | Customer specified identification | |
NJ | CE label | |
NK | ATEX Intrinsic Safety label | |
NSR | Non standard range | |
NX | CSA Intrinsic Safety label | |
NZ | FM Nonincendive label | |
TF | FM Intrinsic Safety label | |
TJ | CSA Div / Zone 2 | |
TW | Russia Intrinsic Safety | |
VD | G2” retaining nut | |
Z () | Alternate electrical connection | |
ZU | irect coupled cable |
ACCESSORIES
Pipe Saddle with shutoff
|
||
Conduit connection box
|
||
Calibration text fixture
|