Model 386 Pressure Transmitter
The Model 386 Flush Tip – Zero Cavity design offers an Isolated sensor assembly that virtually eliminates installation torque effect and is able to withstand pressure spikes up to 1.5x proof pressure and 5x burst pressure (or 30,000 PSI, whichever is less).
PERFORMANCE
Full Scale Pressure Ranges:
|
0-100, 150, 160, 200, 300, 500, 750, 1000, 1500, 2000, 3000, 5000, 7500, 10,000 PSIG / PSIS
|
|
Static Error Band
|
≤±0.5% FSO (Includes BFSL, Hysteresis and Repeatability by RSS)
|
|
Compensated Temperature Range | 70°F to 170°F (21°C to 77°C) | |
Operating Temperature Range |
-40°F to 185°F (-40°C to 85°C) |
|
Storage Temperature Limits | -40°F to 250°F (-40°C to 120°C) | |
Temperature Effect on Zero | ≤±2% FSO per 100°F Typical | |
Temperature Effect on Span | ≤±2% FSO per 100°F Typical | |
Long Term Stability (%FSO) | ≤±0.25% FSO per 6 months |
ELECTRICAL
Supply Voltage:
|
8-28 Vdc
|
|
Power Supply Regulation | <±.05% FSO per volt | |
Output Signal |
4-20 mA |
|
Load Impedance | 926 Ohms maximum at 28 volts DC | |
Circuit Protection | Reverse polarity protected, CE marked | |
RFI / EMI | CE EMC compliant as per IEC EN 61326-1 and EN 61326-2-3 Annex BB | |
Voltage Spike |
Withstand 1000 volt spike per EN 61000-4-5 | |
Insulation Resistance | <5 nS | |
Response Time | <2 mSec for 10-90% of final value | |
Electrical Connection | Bendix PT02E-10-6P, mates PT06E-10-6S (SR) (BH option) | |
Wire Color Code |
Pin A + Power / Signal |
MECHANICAL
Pressure Connection
|
1/2" NPT (M)
|
|
Proof Pressure
|
1.5x
|
|
Burst Pressure | 5X (or 30,000 PSI, whichever is less) | |
Zero Effect from Installation |
<±0.10% at 25 to 50 ft lbs |
MATERIALS OF CONSTRUCTION
Wetted Materials: |
15-5 PH and 304L Stainless Steel (Inconel 718 optional)
|
|
Weight: | 8 oz. nominal |