Model 592 Detachable Level Transmitter
The Model 592 Detachable Level Transmitter allows for a quick sensor swap without the removal of the installed cable. No special tools are required. Simply pull up the sensor, twist the sensor coupling sleeve till it is no longer engaged and then simply separate the two halves.
Common ranges of 592 are available with 2 day turn as part of Viatran's RapidShip Program.
592 is constructed of a Polypropylene High Temperature (PP-HT) housing and 316L stainless steel sensor module, with a polyurethane cable as standard. Different cable materials and o rings are available.
Use it to measure Liquid Level and Depth for Water and Waste Water applications, at Lift Stations, Reservoirs and Dams, Rivers, Holding Ponds, Wells, In-ground / Above Ground Tanks and with Inventory Tank Gauging.
Ranges from 0-40"WC thru 15 'WC have combined accuracy of +/- .50% FSO
Ranges greater than 15' WC have combined accuracy of +/- .35% FSO
Viatran also offers a complete range of accessories for use in level applications such as a surge protector, cable hangers and weights, meters and junction boxes.
Replacement sensor heads and/or cables can be purchased separately
PERFORMANCE
Pressure Ranges | 0 - 40" W.C. up to 0 - 335 Ft W.C. (Or equivalent in Meters or PSI | |
Accuracy [Combined Non-Linearity (BFSL), Hysteresis & Repeatability] | For ranges ≥ 15 Ft. W.C. ≤ +/-0.35% FSO For ranges < 15 Ft. W.C. ≤ +/- 0.50% FSO |
|
Compensated Temperature Range | 32° to 122° F (0 to 50° C) | |
Operating Temperature Range | 32° to 122° F (0 to 50° C) Note: Medium must not freeze near sensor | |
Storage Temperature Range | 14° to 122° F (-10 to 50° C) | |
Long Term Stability (%FSO) | ≤ +/- 0.1% FSO / year (At reference conditions | |
Thermal Effect on Zero | ≤ +/- 1.1% FSO per 100° F | |
Thermal Effect on Span | ≤ +/- 1.1% FSO per 100° F |
ELECTRICAL
Output Signal
|
4-20 mA
|
|
Supply Voltage
|
8 -32 Vdc
|
|
Power Supply Regulation
|
< +/- .005% FSO per volt
|
|
Circuit Protection | Reverse polarity protected, CE marked | |
RFI / EMI | CE EMC compliant as per IEC EN 61326 | |
Voltage Spike Protection | Withstand 1000 volt spike per EN 61000 | |
Response Time | <10 mSec |
MATERIALS OF CONSTRUCTION
Housing
|
PP-HT (Polypropylene High Temperature)
|
|
Sensor Diaphragm
|
316L stainless steel
|
|
O-ring Seals
|
FKM (Standard) or EPDM (Optional)
|
|
Protective Cap | POM (Polyoxymethylene) |
MECHANICAL
Pressure Connection
|
Protective POM cap
|
|
Ingress Protection
|
IP 68
|
|
Overpressure Limit
|
4x Minimum
|
|
Burst Pressure | 5x Minimum | |
Weight | 0.9 lbs. (without cable) |
OPTIONS
EA
|
Special Calibration Run
|
|
PW
|
Calibrate Transmitter with Meter / Display
|