Model 596 Detachable Level Transmitter
When you need to replace your wastewater level transmitter, you don’t have time to wait. Downtime is not an option. With Viatran’s new RapidShip program, the Model 596 Detachable Level Transmitter is available in as little as one 1 to 2 days, and in some cases can be shipped overnight.
The RapidShip program allows you to reduce your inventory costs, minimize your supply chain management effort, eradicate unexpected delays and/or line down situations resulting from peaks in demand.
The Detachable Level Transmitter allows for a quick swap of the sensor head without having to remove your entire cable run. Model 596 is a rugged transmitter that is ideal for higher viscosity media and is resistant to a wide variety of materials. Its semi-flush ceramic sensing face resists clogging and is easily cleaned, allowing it to be used without a cage.
This model can operate in pressure ranges from 0-32 in. w.c. to 0-335 ft. w.c. (or equivilent in meters or PSI )and an operating temperature range of -13° to 185° F (-25° to 85° C). Viatran also stocks six of the most popular polyurethane cable sizes in lengths up to 150 feet (46 meters). When ordering, please specify the range (depth) and cable length needed.
PERFORMANCE
Pressure Ranges | 0-32" W.C. to 0-335 Feet W.C. or equivalent in Meters or PSI | |
Accuracy [Combined Non-Linearity (BFSL), Hysteresis & Repeatability] | ≤ +/-0.1% FSO [Combined Non-Linearity (BFSL), Hysteresis & Repeatability] | |
Compensated Temperature Range | -4° to 176° F (-20 to 80° C) | |
Operating Temperature Range | -13° to 185° F (-25 to 85° C) Note: Medium must not freeze near sensor | |
Storage Temperature Range | -13° to 185° F (-25 to 85° C) | |
Long Term Stability (%FSO) | ≤ +/- 0.1% FSO / year Note: At reference condition | |
Thermal Effect on Zero | ≤ +/- 0.16% FSO per 100° F | |
Thermal Effect on Span | ≤ +/- 0.16% FSO per 100° F |
ELECTRICAL
Output Signal
|
4-20 mA
|
|
Supply Voltage
|
12-36 Vdc
|
|
Power Supply Regulation
|
< +/- .005% FSO per volt
|
|
Circuit Protection | Reverse polarity protected, CE marked | |
RFI / EMI | CE EMC compliant as per IEC EN 61326 | |
Voltage Spike Protection | Withstand 1000 volt spike per EN 61000 | |
Response Time | < 380 mSec |
MATERIALS OF CONSTRUCTION
Housing
|
316L Stainless Steel
|
|
Sensor Diaphragm
|
Ceramic Al2O3 96%
|
|
O-ring Seals
|
FKM (Standard) or EPDM (Optional)
|
|
Removable Protective Cap | POM (Polyoxymethylene) |
MECHANICAL
Pressure Connection
|
Removable Protective POM cap
|
|
Ingress Protection
|
IP 68
|
|
Overpressure Limit
|
5x Minimum (≥ 167 Ft. range = 3.5x)
|
|
Weight | 1.4 lbs. (without cable) |
OPTIONS
EA
|
Special Calibration Run
|
|
PW
|
Calibrate Transmitter with Meter / Display
|
|
ZB | SharkCage Removable Protective Cage | |
NSR | 1/2" NPT Conduit Adapter |