Model 59S Level Transmitter
Designed with a slim 0.75 inch diameter body to enable it to fit small access ports, you can use it to measure Liquid Level and Depth for Water and Waste Water applications, at Lift Stations, Shipboard, In-ground / Above Ground Tanks and with Inventory Tank Gauging.
Have an Application not mentioned above? Need to mount a pressure transmitter directly to a tank? Contact our Application Engineers for assistance in finding the best solution.
PERFORMANCE
Pressure Ranges | 0-50, 100 Inches Water Column, 0-2, 3, 5 PSI | |
Combined Accuracy (Non-Linearity, Hysteresis, Repeatability) | ≤±0.50% FSO for ranges < 15 Ft. W.C. | |
Compensated Temperature Range | 2° to 122° F (0 to 50° C) ≥ 13.4 Ft. W.C., otherwise 32° to 158° F (0 to 70° C) | |
Operating Temperature Range | 14° to 158° F (-10 to 70° C) Note: Medium must not freeze near sensor | |
Storage Temperature Range | -13° to 158° F (-25 to 70° C) | |
Long Term Stability (%FSO) | ≤±0.1% FSO / year at reference conditions | |
Thermal Effect on Zero | ≤ +/- 2% FSO per 100° F for ≥ 13.4 Ft. W.C., otherwise ≤ +/- 0.8% FSO per 100° F | |
Thermal Effect on Span | ≤ +/- 2% FSO per 100° F for ≥ 13.4 Ft. W.C., otherwise ≤ +/- 0.8% FSO per 100° F |
ELECTRICAL
Output Signal
|
4-20 mA (for both the Pressure & Temperature)
|
|
Supply Voltage
|
12-36 Vdc
|
|
Power Supply Regulation
|
<±005% FSO per volt
|
|
Circuit Protection | Reverse polarity protected, CE marked | |
RFI/EMI | CE EMC cmpliant as per IEC EN 61326 | |
Voltage Spike Protection | Withstand 1000 volt spike per EN 61000 | |
Response Time | <10mSec |
MATERIALS OF CONSTRUCTION
Housing
|
316L stainless steel
|
|
Sensor Diaphragm
|
316L stainless steel
|
|
O-ring Seals
|
FKM or EPDM (customer specified)
|
|
Protective Cap | POM (Polyoxymethylene) |
MECHANICAL
Pressure Connection
|
Protective POM cap
|
|
Ingress Protection
|
IP 68
|
|
Overpressure Limit
|
2.4x Minimum
|
|
Weight | 0.22 lbs. (without cable) |
OPTIONS
EA
|
Special Calibration Run
|
|
PW
|
Calibrate item with meter/display
|