Model 509 Hammer Union Pressure Transmitter
Our exclusive semi flush design provides a lower cavity volume to prevent clogging. This eliminates the need for tedious cleaning, especially in cementing applications.
PERFORMANCE
Full Scale Pressure Ranges:
|
0-5K, 10K, 15K, 20K PSIG (0-345, 689, 1034, 1379 bar)
|
|
Combined Accuracy (BFSL):
|
(Non-Linearity, Hysteresis & Repeatability) ≤± 0.25% FSO
|
|
Full Scale Output (FSO):
|
16.00 mA ±1% FSO @70°F
|
|
Zero Balance: | 4 mA ±1% FSO @70°F | |
Long-Term Stability: | ≤±0.25% FSO per 6 months | |
Response Time: |
≤2.5 mSec to reach 90% of FSO | |
Compensated Temperature Range: | -20°F to 185°F (-29°C to 85°C) | |
Operating Temperature Range: | -40°F to 200°F (-40°C to 93°C) | |
Storage Temperature Range: | -67°F to 302°F (-55°C to 150°C) | |
Thermal Effect on Zero: | ≤±1% FSO per 100°F (37°C) | |
Thermal Effect on Span: | ≤±1% FSO per 100°F (37°C) |
ELECTRICAL
Output Signal:
|
4 - 20 mA at 70°F (21°C)
|
|
Supply Voltage:
|
9-30 Vdc (10.5 to 28 Vdc w/approval)
|
|
Power Supply Regulation Effect (Calibrated at 12 Vdc)
|
≤±0.01% FSO per Volt
|
|
Load Impedance: | 750 Ohms maximum at 24 Vdc | |
Circuit Protection: | Varistor protected across the input leads for surges above 1000V at 50 microseconds | |
RFI / EMI: |
<1% FSO output change with 3V Rms from 150 kHz to 80 MGz (80% AM modulated at 1 kHz) applied to power supply and signal lines |
|
Voltage Spike Protection: | Withstand 1000 volt spike per EN 61000-4-5 | |
Insulation Resistance: | ≥100 MegOhms to case ground | |
Response Time: | < 1 millisecond to reach 90% of FSO | |
Range Calibration Signal: | 100% of FSPR | |
Calibration Power Supply Voltage: | 9-30 Vdc at 15 mA nominal | |
Calibration Signal Accuracy: | ≤±0.2% FSO. The exact signal to pressure correlation is provided with each unit | |
Bridge Resistance: | 10K Ohms nominal | |
Standard Electrical Connection: | Mates with Bendix P/N PT06E-10-6S or equivalent | |
PIN OUTS: | PIN A +Power/Signal PIN B -Power/Signal PIN C No connection PIN D No connection PIN E +Calibration PIN F -Calibration Some models are provided with customer specified wiring. Consult Viatran for exact wiring connections. |
MECHANICAL
Standard Pressure Port:
|
Male hammer union 2 inch #1502
|
|
Pressure Cavity Volume:
|
0.4 cubic inches
|
|
Proof Pressure: | 1.67 times the FS or 22.5K PSI (1550 bar) for union #1502 30K PSI (2068 bar) for union #2002 whichever is less |
|
Burst Pressure: |
≥3 times FSPR, limited by union #1502: 22.5K PSI (1550 bar) |
MATERIALS OF CONSTRUCTION
Wetted Materials: |
Inconel X-750, heat treated per MR0175-2000
|
|
Enclosure Material: |
304 stainless steel
|
|
Identification:
|
Laser etched onto body
|
|
Shock Limitation: | 100 G’s | |
Enclosure Rating: | NEMA 4X | |
Weight: | 5.5 lbs nominal (2.4 kg) | |
* Pending approvals |
|
OPTIONS
DH:
|
Special range
|
|
EA |
Special calibration run | |
NJ |
CE label | |
NX |
CSA Intrinsic Safety label |
|
TF |
FM Intrinsic Safety label | |
TP |
Low cavity volume sensor design | |
TW |
Russia Intrinsic Safety | |
ZQ |
CG379-C-145-2P (Glenair) electrical connector | |
ZT | REC-M-10TP-N-04-16 (Jupiter) connector |