Hazardous location transmitters

Model 520 Hammer Union Pressure Transmitter

Model 520 Hammer Union Pressure Transmitter

Viatran's Model 520 Hammer Union Pressure Transmitter offers superior construction and the rugged performance that we have built our reputation on. 

PERFORMANCE

 

Full Scale Pressure Ranges:
0-5K, 0-6K, 0-10K, 0-15K, 0-20K, 0-25K PSIS
Combined Accuracy (BFSL):
(Non-Linearity, Hysteresis & Repeatability) ≤ ± 0.25% FSO
Full Scale Output (FSO):
16.00 mA ±1% FSO @70°F
  Zero Balance: 4 mA ±1% FSO @70°F
  Compensated Temperature Range: -40°F to 140°F (4°C to 60°C)
  Operating Temperature Range: -40°F to 185°F (-40°C to 85°C)
  Storage Temperature Range: -67°F to 302°F (-55°C to 150°C)
  Long Term Stability (%FSO): ≤ ± .25% FSO per 6 months
  Thermal Effect on Zero: ≤± 1% FSO per 100°F Typical
Thermal Effect on Span: ≤± 1% FSO per 100°F Typical

ELECTRICAL

 

Output Signal:
4-20 mA @70°F
Supply Voltage:
9-28 Vdc
Power Supply Regulation:
<± .01% FSO per volt
  Load Impedance: 900 ohms @ 28 VDC decreasing linearity to 0 ohms @ 9 VDC
  Circuit Protection: Reverse polarity protected
  RFI / EMI:

<1% FSO output change with 3V Rms from 150 kHz to 80 MGz

(80% AM modulated at 1 kHz) applied to power supply and signal lines

[IEC 61000-4-6 radio frequency common mode immunity],

1% output change when exposed to a radiated electromagnetic

field of 10 V/m from 80 MHz to 1 GHz AM modulated at 1 kHz and 3 V/m

1.4 GHz to 2.7 GHz. [IEC 61000-4-3 Radiated electromagnetic field immunity]

Voltage Spike Protection: Withstand 1000 volt spike per EN 61000-4-5
Insulation Resistance: < 5 nS
Response Time: < 1 millisecond to reach 90% of FSO
Range Calibration Signal: 100% FSO ±10% by exciting pins E&F
Calibration Power Supply Voltage: 8.5 -28 VDC
Calibration Signal Accuracy: Readings on calibration certificate are within ±0.2% FSO of actual Cal signal output
Bridge Resistance: 10K ohms, nominal
Standard Electrical Connection: Mates with 6 pin, Hermetic, Box Mount, Shell Size 10, MIL-C-26482 bendix type connector
PIN OUTS: PIN A + Power / Signal

PIN B - Power / Signal

PIN C No Connection

PIN D No Connection

PIN E + Calibration

PIN F - Calibration

MECHANICAL

 

 
Standard Pressure Port:
Male hammer union 2 inch #2002
Pressure Cavity Volume:
Standard: 0.45 cubic inches
Zero Effect from Installation:
0.3% FSO w/200 ft-lbs torque on union #2002
  Shock Sensitivity: 1000 g, 0.5 ms half sine wave pulse shall not cause change in calibration
  Proof Pressure: 1.67X range or 30,000 PSI max
  Burst Pressure:

3 Times full scale pressure range, limited by union #2002: 30K PSI

MATERIALS OF CONSTRUCTION

 

 

Wetted Materials:

NACE compliant Inconel 718 (MR0175/ISO 15156-3:2009(E)) 

Enclosure Material:

304 Stainless Steel
Identification:
Laser marked on body of unit
  Enclosure Rating: IP68*, NEMA 6P*
  Weight: 4.0 lbs. nominal
  * Pending approvals

 

OPTIONS

 

 

DC:

Extended Compensated Temperature Range (Cold) -40°F to 140°F (-40°C to 60°C)

DG:

Improved temperature compensation
DH:
Special Range
 

DN:

Improved accuracy
 

EA:

Special Calibration Run
 

EH:

Extended Compensated Temperature Range (Hot) +40°F to 180°F (4°C to 82°C)

 

LW:

Narrow adapter for banding
 

NA:

Carrying handle attached
 

NH:

Customer specific identification

NP:

Protective ring cage
NQ: Protective criss-cross cage

Z():

Special connectors

DIMENSIONS