Model 350 Pressure Transmitter
A flush diaphragm inhibits bacterial growth and facilitates Clean in Place (CIP) systems. The quick-disconnect Tri-clamp connections make these transmitters ideal for pharmaceutical, dairy and food processing applications where frequent cleaning is required.
PERFORMANCE
| Full Scale Pressure Ranges | 0-100, 150. 200, 250, 300, 400, 500, 750, 1K PSIS, PSIA | |
| Combined Accuracy (Non-linearity, Hysteresis, Repeatability) | ≤0.4% FSO | |
| Full Scale Output (FSO) | 16 mA at 70°F (21°C) | |
| Resolution | Infinite | |
| Long Term Stability | ≤±0.25% FSO per 6 months | |
| Pressure Connection Effect Zero Balance | ≤±0.1% | |
| Response Time (mechanical & electrical combined) | 2 Sec (electronically damped) | |
| Temperature Effect on Zero | ≤±2% FSO per 100°F (37°C) | |
| Temperature Effect on Span | ≤±1% FSO per 100°F (37°C) | |
| Operating Temperature Range | 0°F to 180°F (-17°C to 82°C) | |
| Process Temperature Range | -65°F to 250°F (-53°C to 121°C) | |
| Storage Temperature Limits | -65°F to 250°F (-53°C to 121°C) |
ELECTRICAL
|
Sensor Technology
|
Bonded foil strain gage
|
|
|
Supply Voltage
|
10 to 36 Vdc
|
|
|
Power Supply Regulation
|
≤±0.04% FSO per Volt
|
|
| Output Signal | 4 - 20 mA at 70°F (21°C) | |
| Load Impedance | 1300 Ohms max at 36 Vdc | |
| Ripple | ≤±0.08% FSO | |
| Zero Balance | 4 mA ±5% FSO at 70°F (21°C) | |
| Circuit Protection | Varistor protected across the input leads for surges above 38 V nd currents to 250 Amps peak with a pulse width of 8-20 µSecs. Reverse polarity protected | |
| Bridge Resistance | 5000 Ohms nominal | |
| Insulation Resistance | ≤100 MegOhms at 50 Vdc | |
| RFI/EMI Suppression | ≤1% FSO output change at 30 V meter, 10-1000 mhz | |
| Electrical Connection | 1/2” NPT male conduit, 3 wires, 18 AWG, 36” | |
| Wire Color Code |
Red +Power/Signal Black -Power/Signal Green Case Ground |
MATERIALS OF CONSTRUCTION
|
Enclosure Materials
|
15-5, 304, and 316 stainless steel
|
|
|
Wetted Materials
|
316 stainless steel
|
|
| Identification | .Laser etched onto bod | |
| Measured Fluids | Any gas or liquid compatible with 316 stainless steel |
MECHANICAL
|
Pressure Connection
|
1 1/2”, 2”, 2 1/2” Tri-clamp
|
|
|
Proof Pressure
|
1.5 times rated range
|
|
|
Burst Pressure
|
≤3 times rated range or max orange of clamp and tubing, whichever is les
|
OPTIONS
|
BZ
|
Mini change connector
|
|
|
DG
|
Improved temperature compensation
|
|
|
DH
|
Special range
|
|
| EA | Special calibration | |
| JJ | Direct mount indicator with Explosion Proof housing attached to transmitter | |
| MD | FM label | |
| NH | Customer specified identification | |
| NSR | Non-standard range | |
| PW | 1/8 DIN digital indicator | |
| ZP | CIA-C814-10-6P-10-0A1 | |
| NOTE | Application of some available options may affect standard performance. Consult your Viatran Representative for details. |