
Model 59P Level Transmitter
The Model 59P General Purpose Level Transmitter has a 1.38" diameter Polypropylene High Temperature (PP-HT) housing and ceramic sensor. Polyurethane cable is standard. Different cable materials and o-rings are available.
Use it to measure Liquid Level and Depth for Water and Waste Water applications, Lift Stations, Reservoirs and Dams, Rivers, Holding Ponds, Wells, In-ground / Above Ground Tanks and with Inventory Tank Gauging.
Viatran also offers a complete range of accessories for use in level applications such as a surge protector, cable hangers and weights, meters and junction boxes.
PERFORMANCE
Pressure Ranges | 0-13 Feet W.C. to 0-335 Feet W.C. | |
Combined Accuracy (Non-Linearity, Hysteresis, Repeatability) | ≤±0.50% FSO for ranges < 15 Ft. W.C. | |
Compensated Temperature Range | 13° to 158° F (-25 to 70° C) | |
Operating Temperature Range | 32° to 122° F (0 to 50° C) Note: Medium must not freeze near sensor | |
Storage Temperature Range | 14° to 122° F (-10 to 50° C) | |
Long Term Stability (%FSO) | ≤±0.1% FSO / year at reference conditions | |
Thermal Effect on Zero | ≤±0.8% FSO per 100° F | |
Thermal Effect on Span | ≤±0.12% FSO per 100° F | |
Temperature Accuracy | ≤±0.12% FSO per 100° F |
ELECTRICAL
Output Signal
|
4-20 mA
|
|
Supply Voltage
|
8 - 32Vdc
|
|
Power Supply Regulation
|
<±005% FSO per volt
|
|
Circuit Protection | Reverse polarity protected, CE marked | |
RFI/EMI | CE EMC cmpliant as per IEC EN 61326 | |
Voltage Spike Protection | Withstand 1000 volt spike per EN 61000 | |
Response Time | <10mSec |
MATERIALS OF CONSTRUCTION
Housing
|
PP-HT (Polypropylene High Temperature)
|
|
Sensor Diaphragm
|
Ceramic Al2O3 96%
|
|
O-ring Seals
|
PUR, PVC, or FEP (customer must specify)
|
|
Protective Cap | FKM or EPDM (customer must specify) |
MECHANICAL
Pressure Connection
|
Open Face
|
|
Ingress Protection
|
IP 68
|
|
Overpressure Limit
|
1.6x Minimum
|
|
Weight | 0.5 lbs. (without cable) |
OPTIONS
EA
|
Special Calibration Run
|
|
PW
|
Calibrate item with meter/display
|