Model 59T Level and Temperature Transmitter
The Model 59T dual output Temperature/Level Transmitter measures temperatures as low as 32°F thru 158°F. Polyurethane cable is standard. Different cable materials and o rings are available.
Use it to measure Liquid Level and Depth for Water and Waste Water applications, Lift Stations, Reservoirs and Dams, Rivers, Holding Ponds, Wells, In-ground / Above Ground Tanks and with Inventory Tank Gauging.
Ranges from 0-40"WC thru 15 'WC have combined accuracy of +/- .50% FSO
Ranges greater than 15' WC have combined accuracy of +/- .35% FSO
An improved accuracy on ranges >15' is available at 0.25% FSO.
Viatran also offers a complete range of accessories for use in level applications such as a surge protector, cable hangers and weights, meters and junction boxes.
PERFORMANCE
| Pressure Ranges | 0-50, 100 Inches Water Column, 0-2, 3, 5 PSI | |
| Combined Accuracy (Non-Linearity, Hysteresis, Repeatability) | ≤±0.50% FSO for ranges < 15 Ft. W.C. | |
| Compensated Temperature Range | 32° to 158° F (0 to 70° C) | |
| Operating Temperature Range | 14° to 158° F (-10 to 70° C) Note: Medium must not freeze near sensor | |
| Storage Temperature Range | -13° to 158° F (-25 to 70° C) | |
| Long Term Stability (%FSO) | ≤±0.1% FSO / year at reference conditions | |
| Thermal Effect on Zero | ≤±0.8% FSO per 100° F | |
| Thermal Effect on Span | ≤±0.8% FSO per 100° F | |
| Temperature Accuracy | ≤±1.8° F (1°C) | 
ELECTRICAL
| Output Signal | 4-20 mA (for both the Pressure & Temperature) | |
| Supply Voltage | 10 -30 Vdc (for both the Pressure & Temperature) | |
| Power Supply Regulation | <±005% FSO per volt | |
| Circuit Protection | Reverse polarity protected, CE marked | |
| RFI/EMI | CE EMC cmpliant as per IEC EN 61326 | |
| Voltage Spike Protection | Withstand 1000 volt spike per EN 61000 | |
| Response Time | <10mSec | 
MATERIALS OF CONSTRUCTION
| Housing | 316L stainless steel | |
| Sensor Diaphragm | 316L stainless steel | |
| Seals | FKM | |
| Removable Protective Cap | POM (Polyoxymethylene) | 
MECHANICAL
| Pressure Connection | Protective POM cap | |
| Ingress Protection | IP 68  | |
| Overpressure Limit | 4x Minimum | |
| Burst Pressure | 6x Minimum | |
| Weight | 0.5 lbs. (without cable) | 
OPTIONS
| EA | Special Calibration Run | |
| PW | Calibrate item with meter/display | 