Sensors and transducers

Signal signal simulator - VPC-999084

VPC 999084 Transducer Simulator

The VPC-999084 simplifies online troubleshooting for Dynisco sensors, signal conditioners and indicators. Its output can be changed in 20% steps or via a variable potentiometer.

VPC 999084 Transducer Simulator

Accuracy:
±0.25% každého rozsahu stupnice
Bridge resistance:
Vstup: 350 Ohmů ± 2,0% (± 5% v proměnné pozici)
Full performance:
Rotary switch selected full scale ranges of:
0.0 mV/V ±0.25%
1.5 mV/V ±0.25%;
2.0 mV/V ±0.25%
2.5 mV/V ±0.25%
3.0 mV/V ±0.25%
3.33 mV/V ±0.25%
0 to 3.0 mV/V ±5.0%
(variable trim pot) 
  Configuration: 350 Ohms Wheatstone bridge strain gage
  Zero balance: ±0.25% of full scale
  Excitation: 15 Vdc, maximum
  Electrical connector: Bendix PT02A – 10 – 6P substitutes for PT46X,
MDA46X and DYN-X Series
Excitation + Pin C;
Signal + Pin A;
Excitation – Pin D;
Signal – Pin B
  Mass: 500 g
  Note: Each output range has calibrated stages
20%, 40%, 60%, 80% and 100% selected mV / V range. The potentiometer allows continuous adjustment from 0% to 100% 3 mV / V ± 5.0%

PT46x5 Series

PT4605 - Sensor with rigid stem
PT4625 - Sensor with rigid stem and flexible stem
TPT4635 - Combined sensor with rigid stem, flexible stem and built-in temperature sensor

 

The PT46X5 Series transmitter is a +/- 0.5% sensor ideal for general purpose melt pressure measurements requiring simple installation, repeatability and reliability. The PT46X5 transmitters provide the industry standard 0 - 5 Vdc amplified signal designed to work with DCS and PLCs, 1 - 6 Vdc outputs are also available.