- MDA Series
- PT Series
- MDT series
- SPX series
- Echo Series
- Vertex Series
- Industrial series
- Injection Series
- Mercury Free Series
MDT 467
MDT467 - Sensor with flexible and exposed capillary
Sensor with amplifier (signal converter) in version with flexible capillary and exposed membrane. Scanning accuracy better than 1.00% of range. Power supply via 10-36 Vdc. Membrane made of 15-5 PH material and coated with DyMAX®. The length of the fixed rod can be made and adjusted to the required size.
Accuracy better than 0.5%
Power supply 10 -36 V dc
6 Pin connector
R-Cal calibration
Up to 400 °C
For small areas
Flexible capillary
Electrical built-in calibration
Various high level outputs
MDT 435
MDT435 - Sensor with flexible and exposed capillary
Sensor with an amplifier (signal converter) in a version with flexible capillary and exposed membrane. Scanning accuracy better than 0.50% of the range. Power supply via 10-36 Vdc. Membrane made of 15-5 PH material and coated with DyMAX®. The length of the fixed rod can be made and adjusted to the required size.
Accuracy better than 0.25%
Power supply 10 -36 V dc
6 Pin connector
R-Cal calibration
Up to 400 °C
For small areas
Flexible capillary
Electrical built-in calibration
Various high level outputs
MDT 460 | 462 | TDT 463
MDT460 - Sensor with rigid stem
MDT462 - Sensor with flexible capillary.
TDT463 - Sensor with flexible capillary and temperature sensor.
Sensor with integrated amplifier (signal converter). Scanning accuracy better than 1.00% of range. Power supply via 10-36 Vdc. Membrane made of 15-5 PH material and coated with DyMAX®. The length of the fixed rod can be made and adjusted to the required size.
Output signal according to configuration
Accuracy better than 0.50%
Power supply 10 -36 V dc
6 Pin connector
R-Cal calibration
Up to 400°C
MDT 420 | 422 | TDT 432
MDT420 - Sensor with rigid stem
MDT422 - Sensor with flexible capillary.
TDT432 - Sensor with flexible capillary and temperature sensor.
Sensor with integrated amplifier (signal converter). Scanning accuracy better than 0.50% of range. Power supply via 10-36 Vdc. Membrane made of 15-5 PH material and coated with DyMAX®. The length of the fixed rod can be made and adjusted to the required size.
Output signal according to configuration
Accuracy better than 0.25%
Power supply 10 -36 V dc
6 Pin connector
R-Cal calibration
Up to 400°C
PT4676 (0-10Vdc)
Model PT4676 is a special variant of the pressure sensor with flexible capillary and exposed capillary, which has a 0 to 5 Vdc, 1 to 6 Vdc, 0 to10 Vdc, 1 to 11 Vdc outputs signal and is used wherever a conventional fixed rod or flexible capillary sensor cannot be installed due to lack of space. The accuracy of this sensor is better than ±0.5%.
Scanning accuracy ± 0.5%
Output signal 0 to 10 Vdc
Internal 80% calibration
Adjustable zero and sensor range
Exposed capillary
PT4675 (0-5 Vdc)
Model PT4675 is a special variant of the pressure sensor with flexible capillary and exposed capillary, which has a 0-5 VDC output signal and is used wherever a conventional fixed rod or flexible capillary sensor cannot be installed due to lack of space. The accuracy of this sensor is better than ±0.5%.
Scanning accuracy ± 0.5%
Output signal 0 to 5 Vdc
Internal 80% calibration
Adjustable zero and sensor range
Exposed capillary
PT4674 (4-20 mA)
Model PT4674 is a special variant of the pressure sensor with flexible capilary and exposed capillary, which has an output signal of 4-20 mA. It is used wherever a conventional sensor with a fixed rod or flexible capillary cannot be installed due to lack of space.The accuracy of this sensor is better than ±0.5%.
Accuracy ± 0.5%
4-20mA output signal
Internal 80% calibration
Adjustable zero and sensor range
Flexible capillary
Exposed capillary
PT130 | PT140 | PT150 | PT160 Hydraulic sensors
PT130 = 3 mV/V
PT140 = 0-5 VDC
PT150 = 0-10 VDC
PT160 = 4 - 20 mA
This range of hydraulic sensors is designed to measure pressure in injection molding applications. It has a very good resistance to cyclic pressure, which is characteristic of these applications and provide information on the change of the hyd profile. pressure together with information on the stability of the injection system
PT 130 = 3 mV/V
PT 140 = 5 Vdc
PT 150 = 10 Vdc
PT 160 = 4 to 20 mA
Accuracy ± 0.5%
Resistance up to 140°C
Stainless steel construction
Robust design
Internal calibration
Compact dimensions
PT4196 (Oil) 0-10 Vdc
PT4196 sensors provide a standard 0-10Vdc output signal designed to work with DCS and PLC.
The PT4196 is a ± 0.5% accuracy sensor ideal for applications in the food and pharmaceutical industries requiring easy installation, repeatability and reliability. The output signal represents 0-10. The alternative filling of the sensor in the form of oil for the food industry meets the requirements set by the USDA and the FDA.
Accuracy better than ± 0.5%
Alternative charge (oil)
0 - 1000 to 0 - 10,000 psi
0-10 Vdc output signal
Meets FDA and USDA requirements
PT4195 (Oil) 0-5 Vdc
PT4195 sensors provide a standard 0-5Vdc output signal designed to work with DCS and PLC.
It is a sensor with ± 0.5% accuracy ideal for the food or pharmaceutical industry, requiring easy installation, repeatability and reliability. It is filled with mineral oil that meets the requirements of both the USDA and the FDA.
Adjustable zero and span
The cartridge meets FDA and USDA requirements
Accuracy better than ± 0.5%
Stainless steel construction and wetted parts Coated with Dymax®
Output signal 0-5 Vdc
Internal calibration 80%
PT4194 (Oil) 4-20mA
PT4194 Sensors provide an industry standard 4-20 mA amplified signal designed to work with DCS and PLC.
It is a sensor with ± 0.5% accuracy ideal for the food or pharmaceutical industry requiring easy installation, repeatability and reliability. It is filled with mineral oil that meets the requirements of FDA 21 CFR 178.3620, 21 CFR 172.878 and 21 CFR 573.680.
Auto-Zero function
The cartridge meets FDA requirements
Scanning accuracy 0.5%
Output signal 4-20 mA
No calibration required
Ideal for medical and pharmaceutical applications
Excellent abrasion resistance
Auto-Zero
PT418 | PT419 | TPT419 (Oil)
PT418 - Sensor with rigid stem
PT419 - Sensor with rigid stem and flexible stem
TPT419 - Combined sensor with rigid stem, flexible stem and built-in temperature sensor
Model PT418 | PT419 | TPT419 Better than ±0.5% accuracy uses mineral oil as a filler, which meets the requirements of the FDA and USDA and at the same time allows accurate pressure sensing in processes where it is not possible to use mercury fillings. These models are ideal for medical and food or packaging applications.
Output signal 3.33 mV/V
Accuracy better than 0.5%
Special fill material
Meets the requirements of the FDA and USDA
Power supply 10-12 Vdc
Units - PSI
6 Pin connector
Shunt calibration