Characteristics of the PT Series
All sensors in this series can be configured. Optional accessories offer a more resistant membrane against abrasive, aggressive materials or without mercury filling and much more.
Contact us, we will be happy to help you with the configuration.
TPT models are the same as PT, however are equipped with temperature sensors in the form of a thermocouple. J, K, T, E or PT 100 thermocouples are available.
Output signal |
Sensor power supply |
Pressure range |
Units |
Signal converter |
10 - 12 VDC |
0 - 30 000 |
PSI |
PT420 | 422 | TPT 432
PT420A - Sensor with rigid stem
PT422A - Sensor with rigid stem and flexible stem
TPT432A - Combined sensor with rigid stem, flexible stem and built-in temperature sensor
PT420A Series transducer is a ±0.25% sensor ideal for melt pressure applications requiring high accuracy, simple installation, repeatability and reliability.
Output: 3.33 mV/V
Accuracy ±0.25%
Units - PSI
Power supply 10-12 Vdc
8 Pin connector
Shunt calibration
PT460 | 462 | TPT 463
PT460E - Sensor with rigid stem
PT462E - Sensor with rigid stem and flexible stem
TPT463E - Combined sensor with rigid stem, flexible stem and built-in temperature sensor
Sensors with high accuracy ± 1.0% in optional design. Power supply via 10-12 V dc. Membrane made of 15-5 PH material and coated with DyMAX layer. The length of the fixed rod can be made and adjusted to the required size. 6-pin bayonet connector.
Output: 3.33 mV/V
Accuracy ±0.5%
Units - PSI
Power supply 10-12 Vdc
6 Pin connector
Shunt calibration
PT410 | PT412 | TPT412 (NaK)
PT410 - Sensor with rigid stem
PT412 - Sensor with rigid stem and flexible stem
TPT412 - Combined sensor with rigid stem, flexible stem and built-in temperature sensor
The PT 41x series is a sensor with ±0.25% accuracy, which is ideal for food or medical applications. Its alternative filling (NaK), which replaces mercury.
Accuracy ±0.25%
Applicability to 538°C
NaK fill
Inconel membrane
3.33 mV/V output signal
PT418 | PT419 | TPT419 (Oil)
PT418 - Sensor with rigid stem
PT419 - Sensor with rigid stem and flexible stem
TPT419 - Combined sensor with rigid stem, flexible stem and built-in temperature sensor
Model PT418 | PT419 | TPT419 Better than ±0.5% accuracy uses mineral oil as a filler, which meets the requirements of the FDA and USDA and at the same time allows accurate pressure sensing in processes where it is not possible to use mercury fillings. These models are ideal for medical and food or packaging applications.
Output signal 3.33 mV/V
Accuracy better than 0.5%
Special fill material
Meets the requirements of the FDA and USDA
Power supply 10-12 Vdc
Units - PSI
6 Pin connector
Shunt calibration
PT435A
PT435A - Sensor with flexible and exposed capillary
The PT435A series model have been designed for applications where installation space is extremely limited. The exposed part of the capillary allows a bend with a small radius of 3 mm. The specially developed design of the sensor tip facilitates the installation of the sensor in very cramped and confined spaces, where it is not possible to install a standard sensor with a fixed rod or flexible capillary.
0 - 30,000 PSI
Output signal 3.33 mV / V
Accuracy ±0.25%
Power supply 10-12 Vdc
Units - PSI
8 Pin connector
Shunt calibration
Excellent thermal stability and repeatability
Exposed, bendable capillar
PT467E
PT467E - Sensor with flexible and exposed capillary
The PT467E models have been designed for applications where installation space is extremely limited. The exposed part of the capillary allows a bend with a small radius of 3 mm. The specially developed design of the sensor tip facilitates the installation of the sensor in very cramped and confined spaces, where it is not possible to install a standard sensor with a fixed rod or flexible capillary.
0 - 30,000 PSI
Output signal 3.33 mV / V
Accuracy ±0.5%
Power supply 10-12 Vdc
Units - PSI
6 Pin connector
Shunt calibration
Excellent thermal stability and repeatability
Exposed, bendable capillar
PT467XL
PT467XL- Pressure sensor with flexible and exposed capillary In a version with a more durable membrane(XL).
The PT467XL series of pressure transmitters are the ideal choice for applications with high accuracy and minimal mounting space. The PT 467XL models have an accuracy of ± 0.5% of range and an exposed capillary with a diameter of 1.5 mm, which allows bending in a radius of 1/16 inch. The sensors are supplied with a Dymax® membrane, which ensures an increase in wear resistance and thus a longer service life. Sensors marked XL have a protector (flexible capillary) up to the tip of the sensor.
Durable membrane XL
0 - 30,000 PSI
Output signal 3.33 mV / V
Accuracy ±0.25%
Power supply 10-12 Vdc
Units - PSI
6 Pin connector
Shunt calibration
Excellent thermal stability and repeatability
Exposed, bendable capillar
PT415D (NaK)
PT415D - Washable sensor with rigid stem and NaK filling.
The PT415D pressure transmitter with accuracy of better than ±0.5% is the ideal choice for food and medical applications that require high accuracy and easy maintenance. It is a washable sensor with insulated wiring type 1/2-14 NPT or an optional 6-pin hermetically insulated bendix connector. PT 415D contains a high temperature fill (NaK, sodium potassium) and an Inconel membrane. Meets FDA and USDA hygiene regulations and requirements.
Output signal 3.33mV/V
Accuracy better than 0.5%
Washable construction
FDA Certification - (GRAS) for food and pharmaceutical applications
Power supply 10-12 Vdc
Units - PSI
Shunt calibration
Optional 6-pin connector
PT4194 (Oil) 4-20mA
PT4194 Sensors provide an industry standard 4-20 mA amplified signal designed to work with DCS and PLC.
It is a sensor with ± 0.5% accuracy ideal for the food or pharmaceutical industry requiring easy installation, repeatability and reliability. It is filled with mineral oil that meets the requirements of FDA 21 CFR 178.3620, 21 CFR 172.878 and 21 CFR 573.680.
Auto-Zero function
The cartridge meets FDA requirements
Scanning accuracy 0.5%
Output signal 4-20 mA
No calibration required
Ideal for medical and pharmaceutical applications
Excellent abrasion resistance
Auto-Zero
PT4195 (Oil) 0-5 Vdc
PT4195 sensors provide a standard 0-5Vdc output signal designed to work with DCS and PLC.
It is a sensor with ± 0.5% accuracy ideal for the food or pharmaceutical industry, requiring easy installation, repeatability and reliability. It is filled with mineral oil that meets the requirements of both the USDA and the FDA.
Adjustable zero and span
The cartridge meets FDA and USDA requirements
Accuracy better than ± 0.5%
Stainless steel construction and wetted parts Coated with Dymax®
Output signal 0-5 Vdc
Internal calibration 80%
PT4196 (Oil) 0-10 Vdc
PT4196 sensors provide a standard 0-10Vdc output signal designed to work with DCS and PLC.
The PT4196 is a ± 0.5% accuracy sensor ideal for applications in the food and pharmaceutical industries requiring easy installation, repeatability and reliability. The output signal represents 0-10. The alternative filling of the sensor in the form of oil for the food industry meets the requirements set by the USDA and the FDA.
Accuracy better than ± 0.5%
Alternative charge (oil)
0 - 1000 to 0 - 10,000 psi
0-10 Vdc output signal
Meets FDA and USDA requirements
PT4674 (4-20 mA)
Model PT4674 is a special variant of the pressure sensor with flexible capilary and exposed capillary, which has an output signal of 4-20 mA. It is used wherever a conventional sensor with a fixed rod or flexible capillary cannot be installed due to lack of space.The accuracy of this sensor is better than ±0.5%.
Accuracy ± 0.5%
4-20mA output signal
Internal 80% calibration
Adjustable zero and sensor range
Flexible capillary
Exposed capillary