DL Series - Dual-Line Analog Input Process Meter
DL-AC-S4NE
The Viatran DL meter boasts specifications and functionality that make it one of the most advanced process meters available.
Viatran's 24A is one of our most versatile pressure transducers for industrial applications. The 24A measures from 3 PSI to 5000 PSI (0.2 to 345 bar) with standard linearity of ≤±0.25% FSO. Improved linearity of ±0.15% or ±0.10% FSO are available as options. The Model 24A has an 0 - 5 Vdc Output Signal as standard. (Options available)
Typical Applications:
• Engine test stands
• Production test stands
• Hydraulic
• Compressors & Pumps
• Rolling mills
• Die Casting
Contact our Application Engineers today to customize this unit to meet your specific needs.
Configure your own product according to your requirements and needs. If you are unsure of the configuration, provide us in the notes the necessary information about the existing sensor or product, even a competitor. We will be happy to help you find an alternative Viatran product. If your request is urgent, let us know. We will do our best to help you resolve this situation to your satisfaction as quickly as possible. If we have all the information, we are able to offer a model with minor differences, which is in stock and you can have another product available the next day.
If you need more information do not hesitate to contact us.
Full Scale Pressure Ranges:
|
0-3 thru 5000 PSIG (PSIS FOR >500 PSI) (0.2 thru 345 bar)
0-15 thru 0-5000 PSIA (0-1.0 thru 0-345 bar) 0-15 PSIV (0-1.03 BarV |
|
Nonlinearity (Best Fit Straight Line)
|
≤±0.25% FSO
|
|
Hysteresis & Repeatability | ≤±0.10% FSO≤±0.10% FSO | |
Full Scale Output (FSO) | 3.0 mV/V dc at 70°F (21°C) ±1% FSO | |
Resolution | Infinite | |
Long Term Stability |
≤±0.3% FSO per 6 months | |
Compensated Temperature Range | 70°F to 170°F (21°C to 77°C) | |
Operating Temperature Range | -40°F to 250°F (-40°C to 121°C) -40°F to 185°F (-40°C to 85°C) |
|
Storage Temperature Limits | -40°F to 250°F (-40°C to 121°C) | |
Temperature Effect on Zero | ≤±2.0% FSO per 100°F | |
Temperature Effect on Span | ≤±2.0% FSO per 100°F | |
* For PSIV and Compound Range units | Temperature Effect on Zero ≤±3.0% per 100°F Compensated Temperature Range 32°F to 170°F (0°C to 77°C) Output Signal 5 mv/V |
Supply Voltage:
|
8 to 30 Vdc at 3.5 mA nominal, 5 mA max
(12 to 30 Vdc for 10 Vdc output option |
|
Power Supply Regulation | ≤±0.01% FSO per volt change over the supply voltage range | |
Output Signal |
0 - 5 Vdc standard (see options) |
|
Zero Adjustment | ±5% FSO min | |
Circuit Protection | Input polarity may be reversed. Output may be short-circuited indefinitely Over voltage protection to 1000 volts according to EN61000-4- | |
Insulation Resistance | <5 nSec to case ground | |
Response Time |
<2 mSec to reach 90% of full scale | |
RFI/EMI Suppression | CE EMC compliant per IEC EN 61326. CE marked | |
Electrical Connection | Bendix PT02E-10-6P, mates PT06E-10-6S (SR) | |
Wire Color Code |
Pin A + Power |
Pressure Connection
|
1/4" - 18 NPT female
|
|
Proof Pressure
|
≤500 PSI (35 bar) 3 times range or 1,200 PSI (80 bar) max
>500 PSI (35 bar) 3 times range or 9,000 PSI (620 bar) ma |
|
Burst Pressure | ≤500 PSI (35 bar) 5 times range or 2,400 PSI (170 bar) max >500 PSI (35 bar) 5 times range or 10,000 PSI (700 bar) ma |
|
Pressure Cavity Volume |
≤500 PSI (35 bar) 1.5 ml |
|
Mounting | May be supported by process pipin |
Wetted Materials: |
316 Stainless Steel
|
|
Housing
|
304L SS
|
|
Identification:
|
Pressure sensitive label
|
|
Weight: | 10 oz (283 g) |
DL-AC-S4NE
The Viatran DL meter boasts specifications and functionality that make it one of the most advanced process meters available.