- MDA Series
- PT Series
- MDT series
- SPX series
- Echo Series
- Vertex Series
- Industrial series
- Injection Series
- Mercury Free Series
PT4656XL
The PT4656XL models represent an optimal solution for precise melt pressure measurement in nozzles or distribution channels within injection molding applications.
The flexible capillary extends from its electronic housing to the positioned tip in the machine melt, ensuring exceptional durability and prolonged sensor lifespan thanks to its robust construction.
1 "bending radius
Inconel 718 membrane
Cap nut for easy installation
Scanning accuracy ± 0.5%
Usable up to 400°C
Zero and range calibration
Optional output signal






PT4194 (Oil) 4-20mA
PT4194 Sensors provide an industry standard 4-20 mA amplified signal designed to work with DCS and PLC.
It is a sensor with ± 0.5% accuracy ideal for the food or pharmaceutical industry requiring easy installation, repeatability and reliability. It is filled with mineral oil that meets the requirements of FDA 21 CFR 178.3620, 21 CFR 172.878 and 21 CFR 573.680.
Auto-Zero function
The cartridge meets FDA requirements
Scanning accuracy 0.5%
Output signal 4-20 mA
No calibration required
Ideal for medical and pharmaceutical applications
Excellent abrasion resistance
Auto-Zero






PT4195 (Oil) 0-5 Vdc
PT4195 sensors provide a standard 0-5Vdc output signal designed to work with DCS and PLC.
It is a sensor with ± 0.5% accuracy ideal for the food or pharmaceutical industry, requiring easy installation, repeatability and reliability. It is filled with mineral oil that meets the requirements of both the USDA and the FDA.
Adjustable zero and span
The cartridge meets FDA and USDA requirements
Accuracy better than ± 0.5%
Stainless steel construction and wetted parts Coated with Dymax®
Output signal 0-5 Vdc
Internal calibration 80%






PT4674 (4-20 mA)
Model PT4674 is a special variant of the pressure sensor with flexible capilary and exposed capillary, which has an output signal of 4-20 mA. It is used wherever a conventional sensor with a fixed rod or flexible capillary cannot be installed due to lack of space.The accuracy of this sensor is better than ±0.5%.
Accuracy ± 0.5%
4-20mA output signal
Internal 80% calibration
Adjustable zero and sensor range
Flexible capillary
Exposed capillary






PT4675 (0-5 Vdc)
Model PT4675 is a special variant of the pressure sensor with flexible capillary and exposed capillary, which has a 0-5 VDC output signal and is used wherever a conventional fixed rod or flexible capillary sensor cannot be installed due to lack of space. The accuracy of this sensor is better than ±0.5%.
Scanning accuracy ± 0.5%
Output signal 0 to 5 Vdc
Internal 80% calibration
Adjustable zero and sensor range
Exposed capillary






PT4676 (0-10Vdc)
Model PT4676 is a special variant of the pressure sensor with flexible capillary and exposed capillary, which has a 0 to 5 Vdc, 1 to 6 Vdc, 0 to10 Vdc, 1 to 11 Vdc outputs signal and is used wherever a conventional fixed rod or flexible capillary sensor cannot be installed due to lack of space. The accuracy of this sensor is better than ±0.5%.
Scanning accuracy ± 0.5%
Output signal 0 to 10 Vdc
Internal 80% calibration
Adjustable zero and sensor range
Exposed capillary






PT4196 (Oil) 0-10 Vdc
PT4196 sensors provide a standard 0-10Vdc output signal designed to work with DCS and PLC.
The PT4196 is a ± 0.5% accuracy sensor ideal for applications in the food and pharmaceutical industries requiring easy installation, repeatability and reliability. The output signal represents 0-10. The alternative filling of the sensor in the form of oil for the food industry meets the requirements set by the USDA and the FDA.
Accuracy better than ± 0.5%
Alternative charge (oil)
0 - 1000 to 0 - 10,000 psi
0-10 Vdc output signal
Meets FDA and USDA requirements






PT130 | PT140 | PT150 | PT160 Hydraulic sensors
PT130 = 3 mV/V
PT140 = 0-5 VDC
PT150 = 0-10 VDC
PT160 = 4 - 20 mA
This range of hydraulic sensors is designed to measure pressure in injection molding applications. It has a very good resistance to cyclic pressure, which is characteristic of these applications and provide information on the change of the hyd profile. pressure together with information on the stability of the injection system
PT 130 = 3 mV/V
PT 140 = 5 Vdc
PT 150 = 10 Vdc
PT 160 = 4 to 20 mA
Accuracy ± 0.5%
Resistance up to 140°C
Stainless steel construction
Robust design
Internal calibration
Compact dimensions






PT139 | PT139A
Dynisco PT139 and PT139A pressure sensors are designed to measure hydraulic pressure in extreme conditions for testing vehicles, stands and other hydraulic and pneumatic applications. These sensors withstand cyclic pressure and provide excellent performance during demanding industrial conditions.
Full power 3 mV/V
Accuracy better than ± 0.5%
The pressure range is from 0-15 PSI to 0-10,000 PSI
Pressure and vacuum support
Extended operating temperature range
Fully welded stainless steel construction
It resists strong shocks and vibrations
Internal 80% calibration
CE approval





PT199 Pressure sensor
The PT199 pressure sensor is designed to measure pressure on turbine systems. Provides information on pressure or temperature in gas or fuel systems such as gas turbines to regulate gas or fuel flow.
Stainless steel construction
Adjustable zero and upper range
Excellent temperature compensation
Ranges 0-15 PSI to 0-15000 PSI
Advanced electronic design
Accuracy ±0.25% PT199B, PT199S, APT199S
Accuracy ±0.5% PT199






PT375 Pressure Transducer
The Dynisco PT 375 pressure transmitter is designed for applications requiring a zero volume pressure port, fast response time and strict cleanliness standards. The high-pressure metal-to-metal seal offers reliable pressure measurement of sludges, viscous liquids and other media that can be homogenized.
3 mv/v output
Accuracy ±0.50%
Pressure ranges 0-30,000 PSI
Iconel 718 pressure fitting
Zero volume pressure port
Meets cleanability standards
Metal-to-metal pressure seal
Internal 80% shunt calibration






PT311JA Pressure sensor
The Dynisco PT311JA Washable Pressure Sensor is designed for applications requiring a zero volume pressure port. The recessed diaphragm improves the frequency response. The PT311JA has a full 3 mV / V output signal and offers reliable and accurate pressure measurement of gases, viscous liquids.
Flush diaphragm
Accuracy ±0.50%
Zero volume pressure port
15 to 10,000 psi
3 mV/V output
Internal shunt calibration