Viatran's 24A is one of our most versatile pressure transducers for industrial applications. The 24A measures from 3 PSI to 5000 PSI (0.2 to 345 bar) with standard linearity of ≤±0.25% FSO. Improved linearity of ±0.15% or ±0.10% FSO are available as options. The Model 24A has an 0 - 5 Vdc Output Signal as standard. (Options available)

Typical Applications:

• Engine test stands

• Production test stands

• Hydraulic

• Compressors & Pumps

• Rolling mills

• Die Casting

Contact our Application Engineers today to customize this unit to meet your specific needs.

Inquiry system 

Configure your own product according to your requirements and needs. If you are unsure of the configuration, provide us in the notes the necessary information about the existing sensor or product, even a competitor. We will be happy to help you find an alternative Viatran product. If your request is urgent, let us know. We will do our best to help you resolve this situation to your satisfaction as quickly as possible. If we have all the information, we are able to offer a model with minor differences, which is in stock and you can have another product available the next day.

If you need more information do not hesitate to contact us.

Viatran Configuration Code:

Your personal data will be processed according to Terms of personal data processing..

MODEL 24A PRESSURE TRANSDUCER

0-5 Vdc output, 3 thru 5K psi, Silicon Sensor


Viatran's 24A is one of our most versatile pressure transducers for industrial applications. The 24A measures from 3 PSI to 5000 PSI (0.2 to 345 bar) with standard linearity of ≤±0.25% FSO.

Viatran's 24A is one of our most versatile pressure transducers for industrial applications. The 24A measures from 3 PSI to 5000 PSI (0.2 to 345 bar) with standard linearity of ≤±0.25% FSO. Improved linearity of ±0.15% or ±0.10% FSO are available as options. The Model 24A has an 0 - 5 Vdc Output Signal as standard. (Options available)

Performance characteristics

Full Scale Pressure Ranges

0-3 thru 5000 PSIG (PSIS FOR >500 PSI) (0.2 thru 345 bar)

0-15 thru 0-5000 PSIA (0-1.0 thru 0-345 bar)

0-15 PSIV (0-1.03 BarV)

Nonlinearity (Best Fit Straight Line) ≤±0.25% FSO
Hysteresis & Repeatability ≤±0.10% FSO
Full Scale Output (FSO) 5Vdc at 70°F (21°C) ±1.0% FSO standard
Resolution Infinite
Long Term Stability ≤±0.3% FSO per 6 months
Compensated Temperature Range 70°F to 170°F (21°C to 77°C)
Process Media Temperature Range -40°F to 250°F (-40°C to 121°C)
Ambient Operating Temperature Range -40°F to 185°F (-40°C to 85°C)
Storage Temperature Limits -40°F to 250°F (-40°C to 121°C)
Temperature Effect on Zero ≤±2.0% FSO per 100°F
Temperature Effect on Span ≤±2.0% FSO per 100°F

Electrical characteristics

Supply Voltage

8 to 30 Vdc at 3.5 mA nominal, 5 mA max(12 to 30 Vdc for 10 Vdc output option)

Power Supply Regulation ≤±0.01% FSO per volt change over the supply voltage range
Output Signal 0 - 5 Vdc standard (see options)
Zero Adjustment ±5% FSO min
Circuit Protection Input polarity may be reversed. Output may be short-circuited indefinitelyOver voltage protection to 1000 volts according to EN61000-4-5
Insulation Resistance <5 nSec to case ground
Response Time <2 mSec to reach 90% of full scale
RFI / EMI Suppression CE EMC compliant per IEC EN 61326. CE marked
Electrical Connection Bendix PT02E-10-6P, mates PT06E-10-6S (SR)
Pin Outs
Pin A+ Power
Pin B- Power
Pin C+ Signal
Pin D- Signal
Pin ENo connection
Pin FNo connection
ShellGround

Materials of Construction

Wetted Parts 316 Stainless Steel
Housing 304L SS
Weight 10 oz (283 g)
Identification Pressure sensitive label

Mechanical characteristics

Pressure Connection 1/4" - 18 NPT female
Proof Pressure ≤500 PSI (35 bar)3 times range or 1,200 PSI (80 bar) max>500 PSI (35 bar)3 times range or 9,000 PSI (620 bar) max
Burst Pressure ≤500 PSI (35 bar)5 times range or 2,400 PSI (170 bar) max>500 PSI (35 bar)5 times range or 10,000 PSI (700 bar) max
Pressure Cavity Volume ≤500 PSI (35 bar)1.5 ml>500 PSI (35 bar)1.5 ml
Mounting May be supported by process piping

Options 

BF
(K)PTIH-10-6P
BG
DIN 43650
BL
WK6-32S
BN
(K)PTIH-8-4P
BQ
(K)PT02H-10-6P
BR
CF3102E-14S-6P
DA
Isolated shunt
DC
Extended Compensated Temperature Range (Cold) -40°F to 170°F (-40°C to 77°C)
DG
Improved temp performance to 0.005% FSO per 1°F
DH
Special ranging
DK
Special shunt calibration setting
DM
Modified full scale output
DN
Improved non-linearity
DQ
Cleaning for oxygen service
EA
Special calibration run
ED
Extra improved linearity (±0.10% FSO)
EH
Extended Compensated Temperature Range (Hot) +70°F to 185°F (21°C to 85°C)
LR
Permanent Laser Mark
LV
Externally powered,Optically Isolated Shunt Cal
NH
Customer specified identification
PW
1/8 DIN digital indicator
Y()
Multiple pressure ports available. Consult factory
ZU
Direct Cable (175°F max temperature) (79°C)
Note:
Application of some available options may affect standard performance.Consult your Viatran representative for details.
 

Drawings

 

 

 

Certificates & Approvals

Overview of Available Certificates and Approvals: Visit this link, which will take you to a page with a comprehensive list of current certificates and approvals for our products. Here, you can verify that our offerings meet the highest standards of quality and safety. More information


E-Learning

Discover the world of our online E-Learning page and find out how to streamline your daily use of our products. Our practical and comprehensive courses and informational materials will show you how to simplify and enhance the use of our technologies, uncover new information and techniques, and optimize work processes. With these resources, you'll achieve higher efficiency, save time, and improve your work results. More information


Instructional Videos

Our instructional videos offer an interactive way to learn about our products. Combining visual and auditory content, they provide practical solutions to common issues, saving you time and avoiding potential problems. If you encounter an issue, our video manuals offer detailed instructions and practical tips to help you resolve it. Available at any time, they provide a convenient resource that complements our technical support. More information


Relevant Articles

Our technical articles offer a practical way to learn more about our products and their use. They provide detailed information and practical tips on how to solve common problems, saving you time and helping you avoid potential issues. If you still encounter a problem, our technical articles offer specific instructions for solving it. They are available at any time and are a convenient source of information that complements our technical support. More information