Multi-purpose pressure transmitters

Model 34A Pressure Transmitter

Model 34A Pressure Transmitter

Viatran's 34A is one of our most versatile pressure transducers for industrial applications. The 34A measures from 3 PSI to 5000 PSI (0.2 to 345 bar) with standard linearity of ≤±0.25% FSO. Improved linearity of ±0.15% or ±0.10% FSO are available as options. The Model 34A has an 4 - 20 mA Output Signal as standard.

Typical Applications:

• Engine test stands

• Production test stands

• Hydraulic

• Compressors & Pumps

• Rolling mills

• Die Casting

Contact our Application Engineers today to customize this unit to meet your specific needs.

Poptávkový systém

Nakonfigurujte si vlastní produkt, podle Vašich požadavků a potřeb. Pokud si s konfigurací nebudete jistí, uveďte do poznámek potřebné informace o stavajícím produktu třeba i konkurenčním. Rádi Vám pomůžeme najít alternativní produkt z řady Viatran. Pokud je Vaše poptávka urgentní informujte nás o tom, uděláme maximum, abychom Vám pomohli tuto situaci vyřešit co nejrychleji. 

Pokud potřebujete více informací, neváhejte nás kontaktovat.

Viatran Configuration Code:

Your personal data will be processed according to Terms of personal data processing..

MODEL 34A PRESSURE TRANSMITTER

4-20 mA output, 3 to 5K psi, Silicon Sensor


Viatran's 34A is one of our most versatile pressure transducers for industrial applictions. The 34A measures from 3 PSI to 5000 PSI (0.2 to 345 bar) with standard linearity of ≤±0.25% FSO.

Viatran's 34A is one of our most versatile pressure transducers for industrial applications. The 34A measures from 3 PSI to 5000 PSI (0.2 to 345 bar) with standard linearity of ≤±0.25% FSO. Improved linearity of ±0.15% or ±0.10% FSO are available as options. The Model 34A has an 4 - 20 mA Output Signal as standard.

Performance characteristics


Full Scale Pressure Ranges
 
0-3 thru 5000 PSIG (PSIS FOR >500 PSI) (0.2 thru 345 bar)
0-15 thru 0-5000 PSIA (0-1.0 thru 0-345 bar)
Nonlinearity (Best Fit Straight Line) 0-15 PSIV (0-1.03 BarV)
Hysteresis & Repeatability ≤±0.25% FSO
Full Scale Output (FSO) ≤±0.10% FSO
Resolution Infinite
Long Term Stability ≤±0.3% FSO per 6 months
Compensated Temperature Range 70°F to 170°F (21°C to 77°C)
Process Media Temperature Range -40°F to 250°F (-40°C to 121°C)
Ambient Operating Temperature Range -40°F to 185°F (-40°C to 85°C)
Storage Temperature Limits -40°F to 250°F (-40°C to 121°C)
Temperature Effect on Zero ≤±2.0% FSO per 100°F
Temperature Effect on Span ≤±2.0% FSO per 100°F

Electrical characteristics

Supply Voltage
8 to 30 Vdc
Output Signal 4 to 20 mA
Zero Adjustment ±5% FSO min
Circuit Protection Input polarity may be reversed. Output may be short-circuited indefinitelyOver voltage protection to 1000 volts according to EN61000-4-5
Insulation Resistance <5 nSec to case ground
Response Time <2 mSec to reach 90% of full scale
RFI / EMI Suppression CE EMC compliant per IEC EN 61326. CE marked
Electrical Connection Bendix PT02E-10-6P, mates PT06E-10-6S (SR)
Pin Outs
Pin A+ Power / Signal
Pin B- Power / Signal
Pin CNo connection
Pin DNo connection
Pin ENo connection
Pin FNo connection
ShellGround

Materials of Construction

Wetted Parts
316 Stainless Steel
Housing 304L SS
Weight 10 oz (283 g)
Identification Pressure sensitive label

Mechanical characteristics

Pressure Connection
1/4" - 18 NPT female
Proof Pressure

≤500 PSI (35 bar)3 times range or 1,200 PSI (80 bar) max

>500 PSI (35 bar)3 times range or 9,000 PSI (620 bar) max

Burst Pressure

≤500 PSI (35 bar)5 times range or 2,400 PSI (170 bar) max

>500 PSI (35 bar)5 times range or 10,000 PSI (700 bar) max

Pressure Cavity Volume

≤500 PSI (35 bar)1.5 ml

>500 PSI (35 bar)1.5 ml

Mounting May be supported by process piping

Options 

BF
(K)PTIH-10-6P
BG
DIN 43650
BL
WK6-32S
BN
(K)PTIH-8-4P
BQ
(K)PT02H-10-6P
BR
CF3102E-14S-6P
DA
Isolated shunt
DC
Extended Compensated Temperature Range (Cold) -40°F to 170°F (-40°C to 77°C)
DG
Improved temp performance to 0.005% FSO per 1°F
DH
Special ranging
DK
Special shunt calibration setting
DM
Modified full scale output
DN
Improved non-linearity
DQ
Cleaning for oxygen service
EA
Special calibration run
ED
Extra improved linearity (±0.10% FSO)
EH
Extended Compensated Temperature Range (Hot) +70°F to 185°F (21°C to 85°C)
LR
Permanent Laser Mark
LV
Externally powered,Optically Isolated Shunt Cal
NH
Customer specified identification
PW
1/8 DIN digital indicator
Y()
Multiple pressure ports available. Consult factory
ZU
Direct Cable (175°F max temperature) (79°C)
Note:
Application of some available options may affect standard performance.Consult your Viatran representative for details.

 

Drawings

 

 

 

Certificates & Approvals

Overview of Available Certificates and Approvals: Visit this link, which will take you to a page with a comprehensive list of current certificates and approvals for our products. Here, you can verify that our offerings meet the highest standards of quality and safety. More information


E-Learning

Discover the world of our online E-Learning page and find out how to streamline your daily use of our products. Our practical and comprehensive courses and informational materials will show you how to simplify and enhance the use of our technologies, uncover new information and techniques, and optimize work processes. With these resources, you'll achieve higher efficiency, save time, and improve your work results. More information


Instructional Videos

Our instructional videos offer an interactive way to learn about our products. Combining visual and auditory content, they provide practical solutions to common issues, saving you time and avoiding potential problems. If you encounter an issue, our video manuals offer detailed instructions and practical tips to help you resolve it. Available at any time, they provide a convenient resource that complements our technical support. More information


Relevant Articles

Our technical articles offer a practical way to learn more about our products and their use. They provide detailed information and practical tips on how to solve common problems, saving you time and helping you avoid potential issues. If you still encounter a problem, our technical articles offer specific instructions for solving it. They are available at any time and are a convenient source of information that complements our technical support. More information