DL Series - Dual-Line Analog Input Process Meter
DL-AC-S4NE
The Viatran DL meter boasts specifications and functionality that make it one of the most advanced process meters available.
The Model 386 Flush Tip – Zero Cavity design offers an Isolated sensor assembly that virtually eliminates installation torque effect and is able to withstand pressure spikes up to 1.5x proof pressure and 5x burst pressure (or 30,000 PSI, whichever is less).
Configure your own product according to your requirements and needs. If you are unsure of the configuration, provide us in the notes the necessary information about the existing sensor or product, even a competitor. We will be happy to help you find an alternative Viatran product. If your request is urgent, let us know. We will do our best to help you resolve this situation to your satisfaction as quickly as possible. If we have all the information, we are able to offer a model with minor differences, which is in stock and you can have another product available the next day.
If you need more information do not hesitate to contact us.
Full Scale Pressure Ranges:
|
0-100, 150, 160, 200, 300, 500, 750, 1000, 1500, 2000, 3000, 5000, 7500, 10,000 PSIG / PSIS
|
|
Static Error Band
|
≤±0.5% FSO (Includes BFSL, Hysteresis and Repeatability by RSS)
|
|
Compensated Temperature Range | 70°F to 170°F (21°C to 77°C) | |
Operating Temperature Range |
-40°F to 185°F (-40°C to 85°C) |
|
Storage Temperature Limits | -40°F to 250°F (-40°C to 120°C) | |
Temperature Effect on Zero | ≤±2% FSO per 100°F Typical | |
Temperature Effect on Span | ≤±2% FSO per 100°F Typical | |
Long Term Stability (%FSO) | ≤±0.25% FSO per 6 months |
Supply Voltage:
|
8-28 Vdc
|
|
Power Supply Regulation | <±.05% FSO per volt | |
Output Signal |
4-20 mA |
|
Load Impedance | 926 Ohms maximum at 28 volts DC | |
Circuit Protection | Reverse polarity protected, CE marked | |
RFI / EMI | CE EMC compliant as per IEC EN 61326-1 and EN 61326-2-3 Annex BB | |
Voltage Spike |
Withstand 1000 volt spike per EN 61000-4-5 | |
Insulation Resistance | <5 nS | |
Response Time | <2 mSec for 10-90% of final value | |
Electrical Connection | Bendix PT02E-10-6P, mates PT06E-10-6S (SR) (BH option) | |
Wire Color Code |
Pin A + Power / Signal |
Pressure Connection
|
1/2" NPT (M)
|
|
Proof Pressure
|
1.5x
|
|
Burst Pressure | 5X (or 30,000 PSI, whichever is less) | |
Zero Effect from Installation |
<±0.10% at 25 to 50 ft lbs |
Wetted Materials: |
15-5 PH and 304L Stainless Steel (Inconel 718 optional)
|
|
Weight: | 8 oz. nominal |
DL-AC-S4NE