DL Series - Dual-Line Analog Input Process Meter
DL-AC-S4NE
The Viatran DL meter boasts specifications and functionality that make it one of the most advanced process meters available.
Designed with a slim 0.75 inch diameter body to enable it to fit small access ports, you can use it to measure Liquid Level and Depth for Water and Waste Water applications, at Lift Stations, Shipboard, In-ground / Above Ground Tanks and with Inventory Tank Gauging.
Have an Application not mentioned above? Need to mount a pressure transmitter directly to a tank? Contact our Application Engineers for assistance in finding the best solution.
Configure your own product according to your requirements and needs. If you are unsure of the configuration, provide us in the notes the necessary information about the existing sensor or product, even a competitor. We will be happy to help you find an alternative Viatran product. If your request is urgent, let us know. We will do our best to help you resolve this situation to your satisfaction as quickly as possible. If we have all the information, we are able to offer a model with minor differences, which is in stock and you can have another product available the next day.
If you need more information do not hesitate to contact us.
Pressure Ranges | 0-50, 100 Inches Water Column, 0-2, 3, 5 PSI | |
Combined Accuracy (Non-Linearity, Hysteresis, Repeatability) | ≤±0.50% FSO for ranges < 15 Ft. W.C. | |
Compensated Temperature Range | 2° to 122° F (0 to 50° C) ≥ 13.4 Ft. W.C., otherwise 32° to 158° F (0 to 70° C) | |
Operating Temperature Range | 14° to 158° F (-10 to 70° C) Note: Medium must not freeze near sensor | |
Storage Temperature Range | -13° to 158° F (-25 to 70° C) | |
Long Term Stability (%FSO) | ≤±0.1% FSO / year at reference conditions | |
Thermal Effect on Zero | ≤ +/- 2% FSO per 100° F for ≥ 13.4 Ft. W.C., otherwise ≤ +/- 0.8% FSO per 100° F | |
Thermal Effect on Span | ≤ +/- 2% FSO per 100° F for ≥ 13.4 Ft. W.C., otherwise ≤ +/- 0.8% FSO per 100° F |
Output Signal
|
4-20 mA (for both the Pressure & Temperature)
|
|
Supply Voltage
|
12-36 Vdc
|
|
Power Supply Regulation
|
<±005% FSO per volt
|
|
Circuit Protection | Reverse polarity protected, CE marked | |
RFI/EMI | CE EMC cmpliant as per IEC EN 61326 | |
Voltage Spike Protection | Withstand 1000 volt spike per EN 61000 | |
Response Time | <10mSec |
Housing
|
316L stainless steel
|
|
Sensor Diaphragm
|
316L stainless steel
|
|
O-ring Seals
|
FKM or EPDM (customer specified)
|
|
Protective Cap | POM (Polyoxymethylene) |
Pressure Connection
|
Protective POM cap
|
|
Ingress Protection
|
IP 68
|
|
Overpressure Limit
|
2.4x Minimum
|
|
Weight | 0.22 lbs. (without cable) |
EA
|
Special Calibration Run
|
|
PW
|
Calibrate item with meter/display
|
DL-AC-S4NE