Submersible level transmitters

Model 59S Level Transmitter

Model 59S Level Transmitter

Designed with a slim 0.75 inch diameter body to enable it to fit small access ports, you can use it to measure Liquid Level and Depth for Water and Waste Water applications, at Lift Stations, Shipboard, In-ground / Above Ground Tanks and with Inventory Tank Gauging.

Have an Application not mentioned above? Need to mount a pressure transmitter directly to a tank? Contact our Application Engineers for assistance in finding the best solution.

PERFORMANCE

  Pressure Ranges 0-50, 100 Inches Water Column, 0-2, 3, 5 PSI
Combined Accuracy (Non-Linearity, Hysteresis, Repeatability) ≤±0.50% FSO for ranges < 15 Ft. W.C.
Compensated Temperature Range 2° to 122° F (0 to 50° C) ≥ 13.4 Ft. W.C., otherwise 32° to 158° F (0 to 70° C)
  Operating Temperature Range 14° to 158° F (-10 to 70° C) Note: Medium must not freeze near sensor
Storage Temperature Range -13° to 158° F (-25 to 70° C)
Long Term Stability (%FSO) ≤±0.1% FSO / year at reference conditions
Thermal Effect on Zero ≤ +/- 2% FSO per 100° F for ≥ 13.4 Ft. W.C., otherwise ≤ +/- 0.8% FSO per 100° F
Thermal Effect on Span ≤ +/- 2% FSO per 100° F for ≥ 13.4 Ft. W.C., otherwise ≤ +/- 0.8% FSO per 100° F

ELECTRICAL

 
Output Signal
4-20 mA (for both the Pressure & Temperature)
 
Supply Voltage
12-36 Vdc
 
Power Supply Regulation
<±005% FSO per volt
Circuit Protection Reverse polarity protected, CE marked
RFI/EMI CE EMC cmpliant as per IEC EN 61326
Voltage Spike Protection Withstand 1000 volt spike per EN 61000
Response Time <10mSec

MATERIALS OF CONSTRUCTION

Housing
316L stainless steel
 
Sensor Diaphragm
316L stainless steel
O-ring Seals
FKM or EPDM (customer specified)
  Protective Cap POM (Polyoxymethylene)

MECHANICAL

 
Pressure Connection
Protective POM cap
 
Ingress Protection
IP 68
 
Overpressure Limit
2.4x Minimum
Weight 0.22 lbs. (without cable)

OPTIONS

 
EA
Special Calibration Run
 
PW
Calibrate item with meter/display